ASME certified by EKI.  Certificate 

plate is on the front center of the 

vessel. 

 

 
 
 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

 

 

 

Ascent

 & Ascent

 Plus 

 

 

 

 

 

 

 

Combi Boilers 

Model EK1T & EK1T+ - Gas Fired 

 

USER’S INFORMATION MANUAL 

 

MANUFACTURED BY: 

ENERGY KINETICS, INC. 

51 Molasses Hill Road 

Lebanon, NJ 08833 

(908) 735-2066 

 

www.energykinetics.com

 

 

 

INSTALLER: 

PLEASE HANG THIS INFORMATION MANUAL AND ACCESSORY INSTRUCTIONS VISIBLY 
NEXT TO THE BOILER USING THE SUPPLIED POUCH. 

 

CONSUMER:  PLEASE RETAIN THIS INFORMATION MANUAL AND ACCESSORY INSTRUCTIONS FOR 

FUTURE REFERENCE. 

WARNING:  If the information in this 
manual is not followed exactly, a fire 
or explosion may result causing 
property damage, personal injury or 
loss of life. 

 

 

Do not store or use gasoline or 
other flammable vapors and liquids 
in the vicinity of this or any other 
appliance. 

 

WHAT TO DO IF YOU SMELL GAS 

o

 

Do not try to light any appliance. 

o

 

Do not touch any electrical 
switch; do not use any phone in 
your building. 

o

 

Immediately call your gas supplier 
from a ne

ighbor’s phone.  Follow 

the gas supplier’s instructions. 

o

 

If you cannot reach your gas 
supplier, call the fire department. 

 

Installation and service must be 
performed by a qualified installer, 
service agency or the gas supplier.

 

MH27877 

ANSI Z21.13b-2017 

Low-Press Boiler 

 
 
 

 

 

 

 

 

National Board 

Listed 

For Polypropylene Venting 

For Conventional Venting

 

Содержание Ascent Combi Boilers

Страница 1: ...followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or a...

Страница 2: ...rner Do not use or store laundry products paint varnish thinner or other such chemicals near or in the same room as the burner boiler These chemicals cause creation of acids in the burner heat exchang...

Страница 3: ...place any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above 2 Set the thermostat s and aquastat s to their lowes...

Страница 4: ...INSTALLER CITY STATE DATE INSTALLED NOTES TABLE OF CONTENTS Page Topic 2 Please Read This First 4 Record of Installation 4 Table of Contents 5 Installer Note 6 Ascent Combi Boiler 6 Ascent Combi Boile...

Страница 5: ...must be provided with a low water cutoff device A boiler should be installed in such a manner that if the pressure vessel or any connection thereto should leak the resulting flow of water will not ca...

Страница 6: ...t all times This is similar the way traditional tankless coil boilers operate although they typically maintain significantly higher temperatures than are required by the EK1T Ascent Combi and the EK1T...

Страница 7: ...and peak performance and to verify proper performance of all safety devices PERIODIC MAINTENANCE The Ascent Combi and the Ascent Plus Combi boilers require minimal attention from the user Daily inspe...