4. Insert the first CR123A camera type battery provided with your system into the
battery cradle. Then insert the second CR123A battery into its cradle.
5.
The sensor will have sent a “learning in” signal upon first power up and should now
be programmed into position S4.
6.
If you have difficulty with this method you may alternatively depress the small round
BLACK button inside the sensor. This will “force” a learning signal only.
7.
Verify that the sensor is learned into place as indicated by a SOLID RED LED over
position S4 on the Controller.
8.
Once the sensor has been learned in you will need to test the signal transmission.
Please skip to section 6.4 TESTING YOUR SENSORS on page 40 of your Energy
Eye Installation and Operations Manual. PLEASE IGNORE POINTS 8 and 9 as
they do not apply to the EE-IR-05 Sensor.
9.
After the sensor has been learned in, and the signal transmission has been verified
you the jumpers located inside the PIR MUST be programmed. By altering the
jumper settings you will change the LED flashing patterns which greatly affects
battery life. During jumper programming always ignore the 7 prongs on the far
edge of the sensor.
a. ECONOMICAL SETTING – This setting turns OFF all LED activity on
the PIR. This setting will yield the longest battery life for the sensor.
REMOVE THE JUMPER MARKED “P3” and make sure the 3
pronged jumper marked “P2” next to it is in the lower position (see
following picture).