ENERGOPOMIAR ELEKTRYKA TKP-1 Скачать руководство пользователя страница 5

VACUUM CHAMBERS TESTING DEVICE     TKP-1 Type 

 

Page 5 

3.

 

STRUCTURAL DESCRIPTION

 

 

 

Vacuum Chambers Tester Type 

TKP-1

 is placed in the suitcase made of a highly mechanical 

resistant material.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply 

This device is supplied from 230V, 50Hz zero-phase network. Internal, measuring and control 

circuits are secured with a 2A fuse. The device is powered up using the power supply switch on the 

side  edge.  In emergency,  use  the  safety  switch  to  power  down  and  stop  the  operation  of  the 

device. The switch is released by rotating the dial clockwise. 

W

W

a

a

r

r

n

n

i

i

n

n

g

g

 

 

L

L

E

E

D

D

 

 

A

A

T

T

T

T

E

E

N

N

T

T

I

I

O

O

N

N

 

 

!

!

 

 

H

H

I

I

G

G

H

H

 

 

V

V

O

O

L

L

T

T

A

A

G

G

E

E

 

 

H

H

V

V

 

 

c

c

a

a

b

b

l

l

e

e

 

 

c

c

o

o

n

n

n

n

e

e

c

c

t

t

i

i

o

o

n

n

 

 

s

s

o

o

c

c

k

k

e

e

t

t

 

 

T

T

E

E

S

S

T

T

 

 

b

b

u

u

t

t

t

t

o

o

n

n

 

 

D

D

e

e

v

v

i

i

c

c

e

e

 

 

p

p

o

o

w

w

e

e

r

r

 

 

s

s

u

u

p

p

p

p

l

l

y

y

 

 

s

s

w

w

i

i

t

t

c

c

h

h

 

 

R

R

e

e

d

d

 

 

c

c

o

o

n

n

t

t

r

r

o

o

l

l

 

 

l

l

i

i

g

g

h

h

t

t

 

 

 

 

L

L

C

C

D

D

 

 

d

d

i

i

s

s

p

p

l

l

a

a

y

y

 

 

G

G

r

r

e

e

e

e

n

n

 

 

c

c

o

o

n

n

t

t

r

r

o

o

l

l

 

 

l

l

i

i

g

g

h

h

t

t

 

 

T

T

h

h

e

e

r

r

m

m

a

a

l

l

 

 

p

p

r

r

i

i

n

n

t

t

e

e

r

r

 

 

C

C

o

o

n

n

t

t

r

r

o

o

l

l

 

 

k

k

e

e

y

y

b

b

o

o

a

a

r

r

d

d

 

 

H

H

V

V

 

 

c

c

a

a

b

b

l

l

e

e

 

 

 

 

S

S

a

a

f

f

e

e

t

t

y

y

 

 

e

e

m

m

e

e

r

r

g

g

e

e

n

n

c

c

y

y

 

 

s

s

w

w

i

i

t

t

c

c

h

h

 

 

G

G

r

r

o

o

u

u

n

n

d

d

i

i

n

n

g

g

 

 

c

c

l

l

a

a

m

m

p

p

 

 

 

 

s

s

e

e

c

c

o

o

n

n

d

d

 

 

D

D

C

C

 

 

v

v

o

o

l

l

t

t

a

a

g

g

e

e

 

 

p

p

o

o

l

l

e

e

 

 

T

T

E

E

S

S

T

T

 

 

b

b

u

u

t

t

t

t

o

o

n

n

 

 

U

U

S

S

B

B

 

 

s

s

o

o

c

c

k

k

e

e

t

t

 

 

Содержание TKP-1

Страница 1: ...VACUUM CHAMBERS TESTING DEVICE Type TKP 1 TECHNICAL DESCRIPTION AND OPERATION MANUAL And I don t have one yet I m happy because I have a perfect Polish product...

Страница 2: ...product consists of different materials some of them are recyclable others require disposal which means you need to obtain information on the recycling or disposal systems for this kind of products i...

Страница 3: ...u ut t c ci ir rc cu ui it t 6 6 C Co on nt tr ro ol l k ke ey yb bo oa ar rd d 6 6 C Co on nt tr ro ol l b bu ut tt to on ns s a an nd d c co on nt tr ro ol l l li ig gh ht ts s 6 6 M ME EN NU U o op...

Страница 4: ...rrent rate as the DC voltage is generated 2 TECHNICAL DATA Rated voltage of device power supply 230V 50Hz Max power consumption approx 400VA Adjustment range of output voltage 10 80 kV DC every 1kV De...

Страница 5: ...ni in ng g L LE ED D A AT TT TE EN NT TI IO ON N H HI IG GH H V VO OL LT TA AG GE E H HV V c ca ab bl le e c co on nn ne ec ct ti io on n s so oc ck ke et t T TE ES ST T b bu ut tt to on n D De ev vi...

Страница 6: ...te the cursor to the right while setting the date and time to decrease the set output voltage to increase the set output voltage to decrease the set current detection to increase the set current detec...

Страница 7: ...s the factory number of the TKP 1 tester from which the memory was transferred If there are two files with the same name the old one will be overwritten by the new file To leave the viewing of the men...

Страница 8: ...rectness of the result it is advisable to repeat the test on the same chamber but after changing the DC voltage polarity To do this change the places of connecting the HV cable and neutral wire to the...

Страница 9: ...ect are damaged the device must be immediately disconnected from the power supply network 4 The device generates the signals that are dangerous for human life therefore it is necessary to strictly fol...

Страница 10: ...on the conducted tests and measurements it has been confirmed that the Vacuum Chambers Tester Type TKP 1 Factory No meets the requirements specified in the device technical data Zak ad Pomiarowo Badaw...

Страница 11: ...ttery packs batteries connecting wires and cables laboratory clamps and other parts with a specific period of use etc 3 In order to be able to use the rights arising out of this warranty upon applying...

Страница 12: ...nufacturer so that the warranty seal is compromised or there is any other intervention into the Product e whose Warranty Card or serial numbers are changed blurred or erased in any way f damaged in ef...

Отзывы: