background image

 
 
 

 
3         
 

8 Star Energy Pty Ltd | Level 35, 477 Collins Street, Melbourne VIC 3000 | https://www.energizersolar.com 
8 Star Energy ESS Ltd | The Black Church, St Mary’s Place, Dublin DO7 P4AX, Ireland 

2  Important notes 

2.1  Scope 

This  manual  describes  the  assembly,  installation, 
commissioning, maintenance and troubleshooting of 
Energizer Solar Panels.   

2.2  Target group   

This  manual  is  for  qualified  personnel  only.  The 
tasks described in this manual need to be performed 
by professional, suitably qualified technicians only. 

2.3  Safety 

Please  read  all  the  instructions  in  this  manual 
carefully before installation, as well as electrical and 
mechanical requirements. 

The  installation  and  operation  of  photovoltaic 
modules  requires  professional  skills  that  only 
professionals  can  do.  The  installation  process  is 
strictly  observed  with  all  safety  precautions  in  this 
manual and the manual is kept for further reference. 
At the same time, the installer must inform the end 
customer (or consumer) of the above accordingly. 

2.4  Purpose   

This  manual  provides  detailed  instructions  and 
important  safety  precautions  for  the  installation, 
electrical 

connection 

and 

maintenance 

of 

single-sided 

Energizer

  Solar  crystalline  silicon 

photovoltaic  modules  (hereinafter  referred  to  as 
photovoltaic  modules).  This  document  applies  to 
photovoltaic module types listed below.   

ENSP60M1xxx 

ENSP72M1xxx 

ENSP54M2xxx 

ENSP72M2xxx 

Table 1: Photvoltaic module types. 

2.5  Limitation of liability   

Since  the  use  of  this  manual  and  the  installation, 
operation,  use  and  maintenance  of  photovoltaic 
modules  are  beyond  the  control  of  8  Star  Energy 
Proprietary  Limited  (hereafter  “8  Star  Energy”),  this 
manual  does  not  have  any  warranty  meaning, 
whether express or implied. 8 Star Energy will not be 

responsible for any form of injury, including, but not 
limited to, damage, loss of life or additional expenses 
caused  by  incorrect  installation,  operation,  use  and 
maintenance of photovoltaic modules and systems. 

Energizer

  Solar  reserves  the  right  to  update  this 

manual  without  prior  notice.  If  there  are 
inconsistencies in the descriptions between different 
language  versions  of  this  manual,  the  English 
version will prevail.   

3  Laws and regulations 

The  mechanical  and  electrical  installation  of 
photovoltaic  modules  should  be  carried  out  in 
accordance  with  applicable  laws  and  regulations, 
including  electrical  law,  building  law  and  electrical 
connection  requirements.  These  regulations  vary 
depending  on  the  installation  location,  such  as  the 
roof of the building, the surface of the water, etc., or 
may  vary  depending  on  the  installation  system 
voltage, dc usage, or AC. Please contact your local 
authority for specific terms. 

4  Safety measures 

 

Energizer

 Solar modules are designed to meet 

the requirements of IEC 61215 and IEC 61730, 
application class A. 

  Modules  rated  for  use  in  this  application  class 

may  be  used  in  system  operating  at  greater 
than  50V  DC  or  240W,  where  general  contact 
access  is  anticipated.  Class  C  fire  rating 
(IEC61730)and Category 4 fire rating (UL61730) 
are available 

 

All  safety  rules  should  be  read 
and 

understood 

before 

installing, 

wiring, 

etc. 

maintaining  photovoltaic  modules.  When 
the  photovoltaic  module  is  exposed  to 
sunlight  or  other  light  sources,  direct 
current  is  generated.  Direct  contact  with 
the  live  part  of  the  photovoltaic  module, 
such  as  terminals,  whether  or  not  a 

Содержание Beam Series

Страница 1: ...ilicon PV Modules Installation Manual Version 1 0 Released in November 2021 This guide describes how to install the Energizer Solar Beam crystalline silicon PV modules To prevent improper operation be...

Страница 2: ...nergy ESS Ltd The Black Church St Mary s Place Dublin DO7 P4AX Ireland 1 Table of contents 1 Table of contents 2 2 Important notes 3 3 Laws and regulations 3 4 Safety measures 3 5 Handling and unpacki...

Страница 3: ...ntrol of 8 Star Energy Proprietary Limited hereafter 8 Star Energy this manual does not have any warranty meaning whether express or implied 8 Star Energy will not be responsible for any form of injur...

Страница 4: ...ive oil bone setting water thinner adhesive sheets that can generate oxime gas and potting glue only for connectors Such as KE200 CX 200 chemlok etc TBP plasticizer detergent etc to avoid chemical dam...

Страница 5: ...voltaic module and the installation surface should be kept to prevent the installation surface from touching the junction box When installing on the roof comply with the fire protection requirements o...

Страница 6: ...he original packaging box before installation Please protect the packaging from damage It is necessary to protect the safety of photovoltaic modules when unloading especially when hoisting roof projec...

Страница 7: ...e system design requirements the color of photovoltaic modules in the same row or square array should be the same 6 Mechanical installation 6 1 Installation conditions Recommended ambient temperature...

Страница 8: ...a third party testing organization with static mechanical analysis capabilities to meet the country region or corresponding international standards The photovoltaic module must be firmly fixed on the...

Страница 9: ...gure 4 or Figure 5 The 400mm pitch mounting hole size is 7x10mm and 4 x M6 stainless steel bolts are required Figure 5 Secure each bolt to the frame with stainless steel washers one for each side of t...

Страница 10: ...ar PV modules otherwise this may affect the modules operation or performance Be sure to avoid shadowing effects from the module clamps Weep holes on the module frame must not be closed or obscured by...

Страница 11: ...stallation method Figure 2 3 Fig 4 Fig 7 Fig 8 Fig 5 ENSP60M1 ENSP60M1 BL 1755 1038 30 1765 1048 35 1755 1038 30 1765 1048 35 5400Pa 2400Pa 5400 2400Pa Installation scope 400 50mm 1800 1800Pa Installa...

Страница 12: ...nditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at standard test conditions Accordingly the value of Isc marked on this module...

Страница 13: ...ng coil and wire clip must be used to fix it on the bracket Avoid direct sunlight and water soaking cables Please keep the connector dry and clean and make sure that the nut of the connector is tighte...

Страница 14: ...Note that the copper wire cannot be attached directly to the aluminum Put the bolt through the cut washer and then through the hole in the aluminum frame Add the spring washer and nut on the other si...

Страница 15: ...t necessary to clean the PV module rain will have a self cleaning effect If there is a lot of dirt on the surface of the photovoltaic module which has seriously affected the power generation use water...

Отзывы: