ENERGIE
Page | 21
The thermostat cannot be installed:
in exterior walls.
near the radiators, convectors, etc.
behind or near the doors.
near to the windows.
WARNING:
The room thermostat contact (ON / OFF ) must be free of
tension. Connecting a tension on this contact will cause destruction of the
controller.
15.12
Electrical wiring
Model
Power source
Max. current
* Power source cable
section
Inverter
220/240V~ /50Hz
16 A
2,5mm²
*
The above wire sizes are
selected at the maximum current of the unit
according to the European Standard EN60335-1 and
considering a cable
length of 10 meters.
NOTE:
Follow local codes and regulations when selecting field wires, circuit
breakers and earth leakage breakers.
Select the main switches according to the next table:
Model
Power source
Max.
current
CB
ELB
(no. poles/A/mA)
Inverter
220/240V~ /50Hz
16 A
25 A
2/25/30
CB
– Circuit breaker; ELB – Earth leakage breaker.
15.13
Water circulator
Mode selector
Содержание INVERTER 4/12