background image

4

5

This fixture is warranted to perform free from defects for three years. If it fails to do so, you may 

return it with proof of purchase to 13445 12th St., Chino, CA 91710 for replacement.

3. Pass the entire fixture above the suspended ceiling 

grid and align the fixture so that the perimeter of the 

front lens sits flush and secure on the T-grid lip.  Fold 

out each of the 4 safety anchor points (C) and loop 

safety wires through each anchor and secure to 

building structure.

3

Clean with a mild, non-abrasive glass cleaner and soft cloth.  Do NOT use solvents or 

cleaners containing abrasive agents.  When cleaning the fixture, make sure the power is 

turned off, and any liquid spray should be applied to the cleaning cloth and not sprayed 

directly onto the fixture itself.

www.energeticlighting.com

Printed in China

www.energeticlighting.com

INSTALLATION INSTRUCTIONS

CARE AND MAINTENANCE

TROUBLESHOOTING

WARRANTY

Problem

Possible Solution

Corrective Action

Fixture does not light.

Circuit breaker trips 

when light is turned on.

1. Power is off.

2. Incorrect wire connection.

3. Defective wall switch.

Crossed wires or power 

wire is grounded out.

Verify wires are correctly 

connected.

1. Check circuit breaker 

or wall switch.

2. Check wire splices.

3. Replace switch.

A

C

4. Connect the fixture wires to the supply wires - black 

to black (Line), white to white (Neutral), and green to 

green (Ground).

If dimming will be enabled, connect the gray and 

purple wires to the supply dimming leads as well.

Once wire connections are made, secure each with a 

wire nut (AA).  Replace the Driver Compartment 

access panel and secure the panel with screw.

4

A

AA

2. Route building supply wires through access panel (B) 

knock out and secure conduit to access panel with 

adapter (not supplied).

2

B

Отзывы: