3. 

INSTALLATION 

3.1. 

PRELIMINARY PROCEEDINGS 

 

After the unpacking, check the battery in order to exclude possible mechanical damages. Don’t use the battery if 
damaged. If you are not sure, pls. contact your supplier. 
Verify the correct polarity of the whole plant that  you will connect. The polarity is indicated on the connector of 
the battery through the following symbols : 

+

 

positive           

-

 

 

negative

 

3.2. 

PLACE OF INSTALLATION 

Set the battery far from possible heat sources. Pls. look at the specifications contained in the chapter 
“ TECHNICAL DATA “ in order to find the allowed working temperature. 
In case of installation on vehicles , the battery case must be suitably protected from water splashes , sunbeams 
and errant objects. Block the battery in a safe way, using, if necessary , some spongy material in order to fill the 
box. 

3.3. 

CONNECTION 

Use the cables for the appropriate section power connection. We advice to connect before the first negative 
pole and then the positive one. 

 

IF NOT PRESENT, PUT A FUSE WITH AN APPROPRIATE VALUE BETWEEN THE BATTERY AND THE PLANT. 

 

IT’S  NOT  ALLOWED  THE  REPLACEMENT  OF  THE  SCREWS  PRESENT  ON  BATTERY  POLES  WITH  OTHER  SCREWS  OF 

DIFFERENT LENGHT. 

3.4. 

BATTERY CHARGER 

Like all the Litio technology batteries, ENERGA batteries must be charged with suitable battery chargers 
properly tested in the max current and max tension of end-charge. 
The  battery  charger  must  work  in  a  “  CONSTANT  CURRENT”  regime  that  must  not  exceed  the  max  allowed 
recharge current ( look at the chapter TECHNICAL DATA 

max charge current

 ), until the reaching of the “end-

charge”  tension  (  look  at  the  chapter  TECHNICAL  DATA 

max  end-charge  tension

  )  and  go  on  with  a  “ 

CONSTANT CURRENT” regime until the natural zeroing of the supplied current.

 

Moreover,  in  order  to  gain  a  longer  life  for  battery  we  advice  to  charge  it  with  a  current  not  over  the  capacity 
declared from the battery ( for example on the model 13-5° the capacity is 5 A/h and so  you need to charge it 
with not more than 5 Ampere ). 
 

4. 

MAINTENANCE 

The only maintenance needed from battery is the visual control of the connections on poles that 
haven’t to be slow or oxidized. 
 

4.1. 

MAINTENANCE e/o PRESERVATION 

 

For vehicle stop period 

over than 1 week

, being however a little absorption of current from junction box, 

anti-theft device etc.. , you need to maintain the battery charged, using the appropriate maintainers ( look at the 
chapter 

BATTERY CHARGERS

 ) because the 

little 

Litio batteries, damaged seriously themselves in case of 

excessive discharge ( tension lower than 8 Volt ).

 

Содержание 13-3A

Страница 1: ...secuted according to the law The Company reserves the right to make changes and improvements on the machine at any time and without advance notice INSTRUCTION USE AND MAINTENANCE MANUAL Revision 1 date 01 10 2011 Distributor Walkers Garage Ltd Northallerton DL7 9HT 0044 0 1609 777221 LiFePO4 Lithium Starter battery Models 13 3A Ref LITH 120 ...

Страница 2: ...ERAL SAFETY WARNINGS 4 1 2 BATTERY IDENTIFICATION DATA 5 1 3 WARRANTY 5 2 BATTERY FEATURES 6 2 1 NORMATIVE REFERENCES 6 2 2 TECHNICAL FEATURES AND DIMENSIONS 6 3 INSTALLATION 7 3 1 PRELIMINARY PROCEEDINGS 7 3 2 PLACE OF INSTALLATION 7 3 3 CONNECTION 7 3 4 BATTERY CHARGER 7 4 MAINTENANCE 7 4 1 MAINTENANCE E O PRESERVATION 7 ...

Страница 3: ...omposed by A Identification Cover B Index of Chapters C Battery instructions A Identification Cover The cover identifies the battery to which the present Manuali s dedicated In the cover are indicated the following data Builder Logo Battery model Identification code Editorial date Version B Chapters Index The index of chapters numerates the subjects examined by the manual Analytical index develops...

Страница 4: ...ted from NOT AUTHORIZED personnel declares the warranty NO MORE VALID Li ion batteries disposal The batteries signed with the recycling symbol must be treated from a separate collection of rubbish centre recognized from the recycling Agency The batteries must not be mixed togheter with domestic and industrial rubbish Use protective glasses in order to work with battery Not open or dismantle the ba...

Страница 5: ...harge Terms for conservation e o off duty not respected Damages due to a wrong use to be more precise functioning limits overcoming see technical data schedale Deformation or breakage of the box Opening of the box Replacement of the screws present on the poles with others of different lenght Routine service or maintenance effected from NOT qualified personnel Use of battery charter maintainers NON...

Страница 6: ...ndards for Commercial electronic Products EN 50082 1 1997 Low voltage Directive 2006 95 EC European Standard low Vooltage Directive EN 60950 2000 2 2 TECHNICAL FEATURES AND DIMENSIONS Litio Ion BATTERY 13 3 A Nominal voltage 13 2 V Nominal capacity 2 3 A h End charge max voltage 14 5 V End charge min voltage 8 V Discharge max current 5 secs 120 Amp Charge max current 8 Amp Max working temperature ...

Страница 7: ...ENT LENGHT 3 4 BATTERY CHARGER Like all the Litio technology batteries ENERGA batteries must be charged with suitable battery chargers properly tested in the max current and max tension of end charge The battery charger must work in a CONSTANT CURRENT regime that must not exceed the max allowed recharge current look at the chapter TECHNICAL DATA max charge current until the reaching of the end cha...

Отзывы: