Specifications

Item

EN43020

EN43030

Nominal system voltage

Battery input voltage range

12/24 VDC

9V ~ 32V

20A@55˚C

Rated charge/discharge current

Max. PV open circuit voltage

Battery type

Sealed (Default) / Gel/ Flooded

Sealed: 14.4V/ Gel:14.2V/ Flooded 14.6V
Sealed: 14.4V/ Gel:14.2V/ Flooded 14.8V

Bulk/Absorption Charging Voltage

Equalize Charging Voltage

Float Charging Voltage

Low Voltage Reconnect

Low Voltage Disconnect

Self consumption

Charge circuit voltage drop

Discharge circuit voltage drop

LCD temperature range

Working environment temperature

(Controller will produce 100% output at 55˚C)

Relative humidity

Enclosure

Grounding

USB output

Overall dimension

160 x 95 x 50mm

148 x 70mm

Ø4.5mm

181 x 101 x 60mm

172 x 80mm

Ø5.0mm

0.35kg

0.55kg

Mounting dimension

Mounting hole size

Terminals

Net weight

5VDC/2.4A (Total)

Common Positive

IP30

0.29V
0.16V

Sealed/ Gel/ Flooded:12.6V
Sealed/ Gel/ Flooded:11.1V

12V; 18mA/24V; 14.5mA

-18mV/°C >25°C@12V / -36mV/°C >25°C@24V

Sealed/ Gel/ Flooded: 13.8V

-20˚C+70˚C

95% N.C.

-25˚C+55˚C

30A@55˚C

9V ~ 32V

12/24 VDC

12V - 25VOC/24V - 50VOC

www.enerdrive.com.au

Page 15

Содержание ePOWER EN43020

Страница 1: ...SOLAR CHARGE CONTROLLERS Owner s Manual SMART AUTOMATIC 12 24 VOLT PWM SOLAR CONTROLLER 4 STAGE CHARGING EN43020 20A EN43030 30A...

Страница 2: ...he content hereof without obligation or organisation of such revisions or changes unless required to do so by prior arrangement Exclusions For Documentation And Product Usage Unless specifically agree...

Страница 3: ...etc The ePOWER Solar Charge Controller range is built for the toughest Australian conditions using professional level components which have resulted in efficiency increased reliability and performance...

Страница 4: ...R Solar Charge Controller Each time before using the Enerdrive ePOWER Solar Charge Controller READ ALL instructions and cautionary markings on or provided with the controller and all appropriate secti...

Страница 5: ...www enerdrive com au Page 5 FIRE AND OR CHEMICAL BURN HAZARD...

Страница 6: ...vertical surface for maximum cooling efficiency To mount the unit use self tapping screws and mount the unit via the four screw holes supplied and affix to a flat surface 145mm 175mm 70mm 80mm EN43020...

Страница 7: ...istance is within 150mm 3 Always connect the battery first in order to allow the controller to recognize the system voltage 4 Power up the controller and confirm that the LCD screen turns on If the sc...

Страница 8: ...to the battery permanently to keep the battery fully charged by using a process called floating This means the controller will stop charging when the battery is full and will automatically start charg...

Страница 9: ...atus Display www enerdrive com au Page 9 Operation Battery Function Button MENU Button SET Button Browse through screens Load ON OFF Clear error Enter into SET Mode Save data Setting parameter Functio...

Страница 10: ...e 3 Setting temperature on the controller Under the battery temperature screen press the SET button and hold on for 5 seconds to switch between Fahrenheit or Celsius NOTE 1 When the unit is powered up...

Страница 11: ...in 50s 30s 10s and 2s respectively Fault Indication Status Battery over discharge Battery over voltage Battery overheating Load failure Battery level shows empty battery frame blink fault icon blink...

Страница 12: ...e Battery Voltage screen press the SET button and hold for 5 seconds to enter the Battery Type Menu Choose the battery type by pressing the MENU button and then press the SET button to select the chos...

Страница 13: ...uit the output is OFF Temperature sensor is higher than 65 C Temperature sensor is higher than 55 C Temperature sensor is higher than 85 C The battery voltage is above the OVD The battery voltage is b...

Страница 14: ...tions When the battery voltage is restored to or above LVR low voltage reconnect voltage point the load will recover PV array disconnection 1 Battery voltage is lower than 9V 1 Please check the voltag...

Страница 15: ...e circuit voltage drop Discharge circuit voltage drop LCD temperature range Working environment temperature Controller will produce 100 output at 55 C Relative humidity Enclosure Grounding USB output...

Страница 16: ...s or users other than OEM applications This Enerdrive product is not intended for commercial use This warranty does not apply to damage to units from misuse or incorrect installation connection Misuse...

Страница 17: ...to Enerdrive Limitations This warranty does not cover accessories such as adapters and batteries damage or defects result from normal wear and tear including chips scratches abrasions discolouration o...

Страница 18: ...ENERDRIVE PTY LTD P O Box 9159 Wynnum Plaza Queensland Australia 4178 Ph 1300 851 535 Fax 07 3390 6911 Email sales enerdrive com au Web www enerdrive com au...

Отзывы: