Chassis Grounding Connection
DANGER
THIS CHARGER REQUIRES CORRECT GROUNDING.
The unit chassis has to be grounded properly. Never operate the Charger
without proper grounding. Failure to do so may result in poor charger
performance, serious injury or possible death.
Connect the unit’s chassis ground to the common ground point through
the ground stud located near one of the unit mounting slots. See image in
Section 3, page 10.
DC Output Wiring
WARNING: Correct DC Wiring Is Required
The DC wiring used must be of appropriate size. An individual over-current
protection device usually within 20cm of each battery bank is required. A
DC disconnect switch is also recommended. Both devices must be rated for
DC voltage and current and be rated to withstand the short circuit current
available from the connected battery bank. Both devices must match with
the size of the DC wiring.
Recommended Cable Length, Size And Required Fuse Size
Wire Length
Wire Size (mm
2
) - Fuse Size (A)
Model
EN31220
EN31240
EN31260
EN32430
1.5 m
6mm
2
– 30A
12mm
2
– 50A
16mm
2
– 80A
12mm
2
– 30A
2.2m
6mm
2
– 30A
16mm
2
– 50A
25mm
2
– 80A
16mm
2
– 30A
6m
(Not Recommended)
16mm
2
– 30A
35mm
2
– 50A
50mm
2
– 80A
25mm
2
– 30A
Page 17