Enerdrive ePower 300w / 500w Inverter
12V Battery Bank:
• The use of deep cycle battery is highly recommended for power
inverter application.
• For battery size, you need to identify how much you will be using
them between charges. Enerdrive recommends you purchase as
much battery capacity as possible. See more on Battery Run time and
Load in Section 4.
Fuse or Circuit Breaker:
• DC rated fuse or DC rated circuit breaker connected along the DC
positive line is required.
• For EN20300, select a fuse or circuit breaker with a minimum of 40
Adc
• For EN20500, select a fuse or circuit breaker with a minimum of 80
Adc
• Based on the size of the battery bank chosen on the 12V Battery
Bank above, determine the overall short circuit current rating of
the battery bank from the battery manufacturer. The fuse or circuit
breaker chosen has to be able to withstand the short circuit current
that may be generated by the battery bank.
+
+
-
-
Battery
Fuse/Circuit
Breaker