10
Enerdrive ePower 300w / 500w Inverter
Disconnect Switch:
• Select a Disconnect Switch with the same or higher the rating of the
selected fuse or circuit breaker from the above.
• The Disconnect Switch is used to disconnect the DC power
between the ePOWER inverter and the battery bank during service,
maintenance or trouble shooting.
DC Input and Grounding Cable:
• Use of low resistance wire is required for all the DC connections
between the inverter and the battery bank.
• For EN20300, uses minimum 4mm2 wire with maximum cable length
of 1.5 meters.
• For EN20500, use minimum 8mm2 wire with maximum cable length
of 1.5 meters.
Installing the Enerdrive ePOWER Inverter System
WARNING: Electrical Shock Hazard
The unit ‘On/Off’ switch does not disconnect the DC power from
the battery. Use the DC Disconnect Switch or disconnect the DC
input cables connection to disconnect the DC power from the
battery before working on any circuits connected to the unit.
Failure to follow these instructions can result in death or serious
injury.
ePOWER Inverter Installation:
• Choose an appropriate mounting location.
• For indoor use, the orientation of the unit can be mounted in any
direction except with the DC Input panel facing downwards.
• For RV installation, the unit has to be mounted horizontally.
• Use mounting template below to mark the positions of the mounting
screws.
• Drill the 4 mounting holes and place the inverter in position and
fasten the inverter to the mounting surface.