Enerdrive EPL-100AH-12v-BATT Скачать руководство пользователя страница 4

V1.0 1/2015

What’s in the Enerdrive Lithium System?

To use the Enerdrive Lithium Power Pack you need to use two items together.  These are:

•  The actual lithium power pack battery box.
•  The  Advance BMS controller board which includes
•  The Advance BMS Relay Driver box
•  The ePRO Battery Monitor for accurate monitoring and control of the battery pack’s state of charge.  This 

monitor also logs historical data on the batteries usage and provides the trigger switch for a low SOC% or 
Low Overall voltage. The monitor is pre-programmed with all of the alarm set points to match the specific 
installation. The meter will show all of the relative information like Volts, Amps, Amp-hours, Percentage State 
of Charge & Time to go. It will also record all of the history data of the Lithium battery, Deepest Discharge, 
Battery Cycles, Hi/Low Voltage & Amps, All Alarm History Etc. This is a critical part of the Lithium battery 
installation kit.

•  A Blue Sea 500amp main battery latching relay which is activated by the ePRO Battery Monitor when the 

low state of charge (percentage is reached). 

•  A Class T Fuse for system protection.
•  95mm² Battery cable from the battery to the Connection Kit. 

1

2

3

4 5

6

7

8

9

10

11

12

1.  Charge battery indicator
2.  Numeric value indicator field
3.  Setup lock / Master lock indicator
4.  Main battery or Auxiliary battery indicator
5.  State-of-charge bar
6.  Charging in progress indicator
7.  Alarm activated indicator
8.  Readout units
9.  Synchronize indicator
10. Next value or Right key (>)
11.  Menu key
12. Previous value or Left key (<)

Содержание EPL-100AH-12v-BATT

Страница 1: ...Lithium Ion Battery System Owner s Manual V1 0 1 2015 Lithium Power Pack...

Страница 2: ...a tank and even to the extent of being a little bit overkill on the packaging and protection So how does our system actually work The Advance BMS relay driver is designed to take a loop signal wire fr...

Страница 3: ...elay The Advanced BMS Relay Driver will turn the main battery relay OFF every 6min if the SOC on the battery monitor is still below the set point So this may need to be reset a few times before the SO...

Страница 4: ...s Amp hours Percentage State of Charge Time to go It will also record all of the history data of the Lithium battery Deepest Discharge Battery Cycles Hi Low Voltage Amps All Alarm History Etc This is...

Страница 5: ...2 90v 13 00v As you can see here the voltage variance between 100 full and 25 full is only 0 55v This is quite different to lead acid batteries where voltage can range from 12 72v at 100 to 11 88v at...

Страница 6: ...n battery switch and start turning on your loads Keep charging sources connected until the battery reaches maximum charge 100 Q What if I see red lights on on the outputs of the Advance Relay Driver B...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ...that is standard with every Lithium Ion battery kit is pre programmed by Enerdrive to suit the battery configuration Any changes that are made to the pre configuration programming of the ePRO meter wi...

Страница 12: ...nals for lifting or carrying the battery Charging sources that do not have programmable lithium profile configurations and charge voltage between 13 5V and 14 5V no lower than 13 0V and no higher than...

Страница 13: ...or at its option replace it free of charge If the unit is repaired new or reconditioned replacement parts may be used at manufacturer s option A unit may be replaced with a new or reconditioned unit o...

Отзывы: