Please note that there is a power drain of approx 700mA from the battery bank when the Inverter is
running in AC By-Pass mode. In order to avoid draining down the battery bank, a battery charger with
sufficient power is required to maintain the battery bank voltage.
Estimate run time on different 12V Battery Bank Size
AC Load
60AH
120AH
180AH
240AH
300AH
50 W
11 hrs.
22 hrs.
33 hrs.
44 hrs.
55 hrs.
100 W
5 hrs.
11.5 hrs.
17 hrs.
23 hrs.
29 hrs.
200 W
2.5 hrs.
5 hrs.
8 hrs.
11 hrs.
13.5 hrs.
500 W
49 mins
2 hrs.
3 hrs.
4 hrs.
5 hrs.
1000 W
15 mins
49 mins
1.5 hrs.
2 hrs.
2.5 hrs.
1500 W
8 mins
27 mins
49 mins
1 hr
1.5 hrs
2000 W
N.R.
15 mins
34 mins
49 mins
1 hrs
2600 W
N.R.
11 mins
25 mins
37 mins
49 mins
Note: N.R. - Not Recommended