Once the first battery working mode has been entered (the display stops flashing) the next
battery can be inserted and the desired working mode can be chosen accordingly.
When the previous battery slot setting mode is not yet effective (telling by the flashing
display of that battery slot LCD), and the next battery is being inserted, then both battery slot
displays will be flashing, which means that
any setting change will be applied to all
batteries
at the same time.
Once normal working mode starts, charging current or working mode can no longer be
changed, until batteries are taken out from the charger and inserted again, or the MODE
button is pressed for longer than 2 seconds.
During normal working mode, pressing the DISPLAY button will toggle display mode
between battery voltage, working current, elapsed time for all slots which are currently in
working progress. Each button pressed will turn on a back light for 30 seconds.
Operation Mode Selection
● Press and hold the MODE button for 2 seconds to start working mode selection for all
four battery slots.
● Press the MODE button subsequently to toggle between the CHARGE,
DISCHARGE, TEST , QUICK TEST and REFRESH modes (Image 6)
● When a particular slot working mode needs to be changed, detach the battery from
the charger and insert it into the slot again, while that selected slot LCD display
content is flashing, press MODE button to choose the desired operation mode.
● When an operation mode is changed, working current adjustment is possible also.
Current Selection
Within the first 6 seconds after inserting the battery or right after power up, press the
CURRENT button to select the desired charging current for slot(s) currently loaded with a
battery/batteries.
Current setting can not be changed once the setting had been confirmed and the
charging/discharging process has begun. If a different working current is required
afterwards, either change the operation mode, or pull out the battery from its slot and insert it
again.
Discharging current is automatically set to predefined charging current.