Once the first battery working mode has been entered (the display stops flashing) the next

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

battery can be inserted and the desired working mode can be chosen accordingly.  
When the previous battery slot setting mode is not yet effective (telling by the flashing

 

 

 

 

 

 

   

 

 

 

 

 

 

 

display of that battery slot LCD), and the next battery is being inserted, then both battery slot

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

displays will be flashing, which means that

any setting change will be applied to all

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

batteries

 at the same time.  

 
Once normal working mode starts, charging current or working mode can no longer be

 

 

 

 

 

 

   

 

 

 

 

 

 

changed, until batteries are taken out from the charger and inserted again, or the MODE

 

 

 

 

 

 

 

 

 

 

 

   

 

 

button is pressed for longer than 2 seconds. 
 
During normal working mode, pressing the DISPLAY button will toggle display mode

 

 

 

 

 

 

 

 

 

 

 

 

between battery voltage, working current, elapsed time for all slots which are currently in

 

 

 

 

 

 

 

 

 

 

 

 

   

working progress. Each button pressed will turn on a back light for 30 seconds. 

Operation Mode Selection 

  

● Press and hold the MODE button for 2 seconds to start working mode selection for all

 

 

 

 

 

 

   

   

 

 

 

 

   

four battery slots. 

● Press the MODE button subsequently to toggle between the CHARGE,

 

 

 

 

 

 

 

 

 

 

DISCHARGE, TEST , QUICK TEST and REFRESH modes (Image 6) 

 

 

● When a particular slot working mode needs to be changed, detach the battery from

   

 

 

 

 

   

 

 

 

 

 

 

the charger and insert it into the slot again, while that selected slot LCD display

 

 

 

   

 

 

 

 

 

 

 

 

 

 

content is flashing, press MODE button to choose the desired operation mode.   

● When an operation mode is changed, working current adjustment is possible also.  

Current Selection  

Within the first 6 seconds after inserting the battery or right after power up, press the

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

CURRENT button to select the desired charging current for slot(s) currently loaded with a

 

   

 

 

 

 

 

 

 

 

 

   

battery/batteries.  
Current setting can not be changed once the setting had been confirmed and the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

charging/discharging process has begun. If a different working current is required

 

 

 

     

 

 

 

 

 

afterwards, either change the operation mode, or pull out the battery from its slot and insert it

 

 

 

 

 

   

 

 

 

 

   

 

 

   

again. 
Discharging current is automatically set to predefined charging current.  

 
 

 

Distributed by ENERdan GmbH | Max-Planck-Straße 3, D-12489 Berlin, Germany 

[email protected]

 | +49 - (0)30 – 6392-80400 | www.enerdan.de

 

 
 

Содержание BT-C700

Страница 1: ...nt can be selected from 200mA to 1000mA If 4 batteries are being charged then the maximum current for each slot will be limited to 700mA If there is no battery in slots 2 or 3 then the maximum current in slot 1 and 4 can be selected up to 1000mA The charger can charge simultaneously batteries of different types and sizes and with different capacity It also includes the Minus Delta Voltage ΔV funct...

Страница 2: ...nversion and or modification of the device are inadmissible because of safety and approval reasons CE Any usage other than described in this manual is not permitted and can damage the product and lead to associated risks such as short circuit fire electric shock etc Please read the operating instructions thoroughly and keep them for future reference The charger has its backlight turned on after ea...

Страница 3: ... shown until any batteries are inserted image 3 Operation Once a rechargeable battery is inserted its present voltage for example 1 12V will be displayed for 3 seconds then 400mA default charging current will be shown on display for another 3 seconds Image 4 If MODE or CURRENT button image 5 is not pressed during these 6 seconds the charging process will start During the first 6 second time if any...

Страница 4: ...on for 2 seconds to start working mode selection for all four battery slots Press the MODE button subsequently to toggle between the CHARGE DISCHARGE TEST QUICK TEST and REFRESH modes Image 6 When a particular slot working mode needs to be changed detach the battery from the charger and insert it into the slot again while that selected slot LCD display content is flashing press MODE button to choo...

Страница 5: ...hargeable battery is discharged to a preset battery voltage 0 9V Once the discharge is finished the total accumulated discharging capacity will be displayed at mAh showing how much energy is discharged from the battery which is always referring to the accumulated discharging capacity No trickle charge current will be applied after discharge cycle is finished REFRESH Mode The rechargeable battery i...

Страница 6: ...r 500 milliohms it means these batteries are not sufficient for supplying power to high current loads such as digital cameras etc However they can still be used for low energy loads such as clocks remote controllers etc Always use batteries with more or less similar internal resistance when they are used in serial to achieve maximum battery life Alkaline and other 1 5V batteries can be tested on t...

Страница 7: ...Technical Specifications Input Voltage 12V 16VDC Power Supply Input 100 240V 50 60Hz Output 12V DC 1 0A Charging Current Range 200 300 400 500 700 1000 mA Maximal Charging Capacity 20000 mA Operation Temperatures 0 40 C Maintenance The device requires no particular maintenance but should be cleaned occasionally When cleaning the device must be disconnected from any power source Use dry and soft cl...

Страница 8: ... even destroy the product Wait until the product adapts to the new ambient temperature before use Sufficient ventilation is essential when operating the charger Never cover the ventilating slots of the charger Please take precautions especially when ambient temperature is over 35 degrees Celsius and charging current rate is over 0 5C If higher charging current applied it is easier to build up temp...

Страница 9: ...Max Planck Straße 3 D 12489 Berlin Germany Email sales enerdan de Tel 49 0 30 6392 80400 More Information and products at www enerpower de Distributed by ENERdan GmbH Max Planck Straße 3 D 12489 Berlin Germany sales enerdan de 49 0 30 6392 80400 www enerdan de ...

Отзывы: