ENERDAN BT-C700 Скачать руководство пользователя страница 2

● The charger includes overheat detection to protect rechargeable batteries and

 

 

 

 

 

 

 

 

 

 

charger itself from overheating. Specially design improved charging circuit provides

 

 

 

 

 

 

 

 

 

 

excellent heating management during high current charging processes, which

 

 

 

 

 

 

 

 

 

assures the best charging condition for batteries.  

● The charger can only be powered with a power supply rated 12v/1.0A.  
● Operate and store it only in a dry indoor environment.  
● This product fulfills European and German requirements related to electromagnetic

 

 

 

 

 

 

 

   

 

compatibility (EMC).  

● CE conformity has been verified and the relevant statements are available upon

 

 

 

 

 

 

 

 

 

 

 

 

request.  

● Unauthorized conversion and/or modification of the device are inadmissible because

 

 

 

   

 

 

 

 

 

of safety and approval reasons (CE).  

● Any usage other than described in this manual is not permitted and can damage the

 

 

 

 

   

 

   

 

 

 

 

 

 

product and lead to associated risks such as short-circuit, fire, electric shock, etc.  

● Please read the operating instructions thoroughly and keep them for future reference.  
● The charger has its backlight turned on after each keypress. Back light will be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switched off after 30 seconds when no key is pressed.  

● The maximum charging capacity can be up to 20,000mAH.  

Scope of Delivery  

● Battery Charger BT-C700 (Image 1)  1 pcs. 
● Power Adapter 12V / 1A (Image 2) 1 pcs.  
● Operation Instructions 

1 pcs.  

● Optional: 12V charging cable

1 Pcs. 

 

 

 

 

 

 

 

 

Distributed by ENERdan GmbH | Max-Planck-Straße 3, D-12489 Berlin, Germany 

[email protected]

 | +49 - (0)30 – 6392-80400 | www.enerdan.de

 

 
 

Содержание BT-C700

Страница 1: ...nt can be selected from 200mA to 1000mA If 4 batteries are being charged then the maximum current for each slot will be limited to 700mA If there is no battery in slots 2 or 3 then the maximum current in slot 1 and 4 can be selected up to 1000mA The charger can charge simultaneously batteries of different types and sizes and with different capacity It also includes the Minus Delta Voltage ΔV funct...

Страница 2: ...nversion and or modification of the device are inadmissible because of safety and approval reasons CE Any usage other than described in this manual is not permitted and can damage the product and lead to associated risks such as short circuit fire electric shock etc Please read the operating instructions thoroughly and keep them for future reference The charger has its backlight turned on after ea...

Страница 3: ... shown until any batteries are inserted image 3 Operation Once a rechargeable battery is inserted its present voltage for example 1 12V will be displayed for 3 seconds then 400mA default charging current will be shown on display for another 3 seconds Image 4 If MODE or CURRENT button image 5 is not pressed during these 6 seconds the charging process will start During the first 6 second time if any...

Страница 4: ...on for 2 seconds to start working mode selection for all four battery slots Press the MODE button subsequently to toggle between the CHARGE DISCHARGE TEST QUICK TEST and REFRESH modes Image 6 When a particular slot working mode needs to be changed detach the battery from the charger and insert it into the slot again while that selected slot LCD display content is flashing press MODE button to choo...

Страница 5: ...hargeable battery is discharged to a preset battery voltage 0 9V Once the discharge is finished the total accumulated discharging capacity will be displayed at mAh showing how much energy is discharged from the battery which is always referring to the accumulated discharging capacity No trickle charge current will be applied after discharge cycle is finished REFRESH Mode The rechargeable battery i...

Страница 6: ...r 500 milliohms it means these batteries are not sufficient for supplying power to high current loads such as digital cameras etc However they can still be used for low energy loads such as clocks remote controllers etc Always use batteries with more or less similar internal resistance when they are used in serial to achieve maximum battery life Alkaline and other 1 5V batteries can be tested on t...

Страница 7: ...Technical Specifications Input Voltage 12V 16VDC Power Supply Input 100 240V 50 60Hz Output 12V DC 1 0A Charging Current Range 200 300 400 500 700 1000 mA Maximal Charging Capacity 20000 mA Operation Temperatures 0 40 C Maintenance The device requires no particular maintenance but should be cleaned occasionally When cleaning the device must be disconnected from any power source Use dry and soft cl...

Страница 8: ... even destroy the product Wait until the product adapts to the new ambient temperature before use Sufficient ventilation is essential when operating the charger Never cover the ventilating slots of the charger Please take precautions especially when ambient temperature is over 35 degrees Celsius and charging current rate is over 0 5C If higher charging current applied it is easier to build up temp...

Страница 9: ...Max Planck Straße 3 D 12489 Berlin Germany Email sales enerdan de Tel 49 0 30 6392 80400 More Information and products at www enerpower de Distributed by ENERdan GmbH Max Planck Straße 3 D 12489 Berlin Germany sales enerdan de 49 0 30 6392 80400 www enerdan de ...