Enerco HSVFB20LPT Скачать руководство пользователя страница 3

3

Installation Instructions and Owner’s Manual

Unvented LP-Gas Vent Free Room Heaters

9.  Operating heater above elevations of 4,500 feet 

could cause pilot/ODS to shutdown heater.

10. Always run heater with control knob in a locked po

-

sition. Never set control knob between locked posi

-

tions. Poor combustion and higher levels of carbon 

monoxide may result if control knob is left between 

locked positions.

DANGER

: Carbon monoxide poisoning may lead to 

death. 

Carbon Monoxide Poisoning:

Early signs of carbon monoxide poisoning resemble the 

flu, with headaches, dizziness, or nausea. If you have 

these signs, the heater may not be working properly. 

Get fresh air at once! Have heater serviced. Some 

people are more affected by carbon monoxide than oth

-

ers. These include pregnant women, persons with heart 

or lung disease or anemia, those under the influence of 

alcohol, and those at high altitudes.

Propane/LP Gas:

Propoane/LP gas is odorless. An odor making agent is 

added to propane/LP gas. The odor helps you detect 

a Propane/LP gas leak. However the odor added to 

propane/LP gas may be present even though no odor 

exists. Make certain you read and understand all warn

-

ings. Keep this manual for reference. It is your guide to 

safe and proper operation of this heater.

PRECAUTIONS:

1.  BF-20 LPT, BF-30 LPT, IR-20 LPT and IR-30 LPT 

may not be installed in a bedroom or bathroom, or 

any place where a strong wind would shut down the 

appliance.

2.  This heater needs outside ventilation air to run 

properly. The Oxygen Depletion Sensor (ODS) 

safety shutoff system shuts down the heater if not 

enough fresh air is available. See 

Fresh Air for 

Combustion and Ventilation

, pages 5 through 6.

3.  Keep all air openings in heater clear, free of debris 

or any blockage. This will insure that enough air for 

proper combustion enters the heater.

4.  If heater shuts off, do not relight until you provide 

fresh, outside air. If heater keeps shutting off, it 

requires servicing.

5.  Turn off and unplug heater and let cool before 

servicing. Only a qualified service person should 

service and repair heater.

6.  Do not run heater:

 

• 

Where flammable liquids or vapors are used or  

    stored

 

• 

During dusty conditions.

7.  Before using furniture polish, wax, carpet cleaner 

or similar products, turn heater off. If heated the 

vapors from these products may create a white 

powder residue within burner box or on adjacent 

walls or furniture.

8.  Do not use heater if any part has been underwater. 

Immediately call a qualified service technician to 

inspect the room heater and to replace any part of 

the control system and any gas control which has 

been underwater.

SPECIFICATIONS

 

IR20LPT

IR30LPT

BF20LPT

 BF30LPT 

BTU (Available) 

20,000 

30,000 

20,000 

30,000 

Type of Gas 

LP-Gas Only 

LP-Gas Only 

LP-Gas Only 

LP-Gas Only  

Ignition 

Battery ignitor (1-AA)  Battery ignitor (1-AA)  Battery ignitor (1-AA)  Battery ignitor (1-AA) 

Pressure Regulator Setting 

10 Inches of Water 

10 Inches of Water 

10 Inches of Water 

10 Inches of Water 

Inlet Gas Pressure (Maximum) 

14 Inches of Water 

14 Inches of Water 

14 Inches of Water 

14 Inches of Water 

Inlet Gas Pressure (Minimum) 

11 Inches of Water 

11 Inches of Water 

11 Inches of Water 

11 Inches of Water 

Electrical Rating /Blower

120V, 60Hz , 1 

120V, 60Hz , 1 

120V, 60Hz , 1 

120V, 60Hz , 1 

Burners / Orifice nozzles 

1

1

Thermostatic Control 

Yes

Yes 

Yes

Yes

Clearances: inches (mm) 

Top

36” (915cm) 

36” (915cm) 

36” (915cm) 

36” (915cm) 

Sides

10.5” (267cm) 

10.5” (267cm) 

10.5” (267cm) 

10.5” (267cm) 

Floor (min to top of carpet) 2” (51cm) 

2” (51cm) 

2” (51cm) 

2” (51cm) 

Fabric / flammable objects 36” (915cm) 

36” (915cm) 

36” (915cm) 

36” (915cm) 

Содержание HSVFB20LPT

Страница 1: ...ovisions for adequate combustion and ventilation air must be provided Refer to Fresh Air for Combustion and Ventilation section on page 4 of this manual WARNING Improper installation adjustment altera...

Страница 2: ...hildren and adults away from hot surfaces to avoid burns or clothing igni tion Heater will remain hot for a time after shutdown Allow heater surfaces to cool before handling Young children should be c...

Страница 3: ...6 3 Keep all air openings in heater clear free of debris or any blockage This will insure that enough air for proper combustion enters the heater 4 If heater shuts off do not relight until you provide...

Страница 4: ...l Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Com bustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unc...

Страница 5: ...Vent Free Heater 20 000 Btu hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the space can support with the actual amount of Btu hr used Example 51 800 Btu hr maximum Btu hr the space can support 6...

Страница 6: ...pos sible provide greater clearances from the floor ceil ing and joining walls WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh ai...

Страница 7: ...ll be located Make sure mounting bracket is level For wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 7 If you can provid...

Страница 8: ...bottom mounting screw into wall stud drill holes at marked locations using 9 64 drill bit 5 Re place heater onto mounting bracket 6 Place spacers between bottom mounting holes and wall anchor or drill...

Страница 9: ...o 14 W C Pressure Tee Joint 1 8 NPT Plug Tap Cap Pipe Nipple Tee Joint 3 8 NPT Pipe Nipple Sediment Trap Test Gauge Connection Reducer Bushing to 1 8 NPT 3 Minimum CAUTION Use pipe joint sealant that...

Страница 10: ...TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the...

Страница 11: ...t cleaning due to excess lent from carpeting bedding material pet hair etc Make sure grille guard is in place before running heater If screen or grille guard is removed for servicing it must be replac...

Страница 12: ...uum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit ever 2 500 hours of operation or every three months We also...

Страница 13: ...13 Installation Instructions and Owner s Manual Unvented LP Gas Vent Free Room Heaters This page intentionally left blank...

Страница 14: ...regulator 6 Turn Control knob to pilot position When ignitor button is pressed in there is a spark at the ODS pilot but no ignition 1 Control knob not fully pressed in 2 Control knob not pressed in lo...

Страница 15: ...ee Figure 4 page 7 4 Clean burner orifice see Cleaning and Maintenance on pages 11 and 12 or replace burner orifice White powder residue forming within burner box or on adjacent walls or furni ture 1...

Страница 16: ...eaters IR20LPT IR30LPT BF20LPT BF30LPT 7 2 36 39 38 35 16 21 16 1 16 2 6 26 29 24 22 3 13 23 18 3 11 1 2 1 4 22 2 33 1 22 1 25 9 5 1 3 1 1 27 1 28 1 4 44 42 45 8 20 10 15 14 42 9 7 26 22 3 22 1 33 1 1...

Страница 17: ...Thermostat Valve assembly 1 9 70641 70641 70641 70641 Ignitor Module Mounting Bracket 1 10 70682 70682 70682 70682 High Limit Switch 1 11 70644 70644 70644 70644 Ignitor Module Battery powered 1 12 70...

Страница 18: ...in Relief Grommet 1 70689 70692 Right Burner Gas Tube 1 70690 70693 Right Middle Gas Burner Tube 1 70598 Left Middle Gas Burner Tube 1 70691 70694 Left Burner Gas Tube 1 70695 70695 70696 70696 ODS Ga...

Страница 19: ...19 Installation Instructions and Owner s Manual Unvented LP Gas Vent Free Room Heaters This page intentionally left blank...

Страница 20: ...ctory FOR INFORMATION REGARDING SERVICE Please call Toll Free 800 251 0001 www mrheater com Our office hours are 8 30 AM 5 00 PM EST Monday through Friday Please include the model number date of purch...

Отзывы: