Enerco HeatStar HSVFB10NG Скачать руководство пользователя страница 3

3

Installation Instructions and Owner’s Manual

Unvented Natural Gas Fired Room Heater

DANGER

: Carbon monoxide poisoning may lead to 

death. 

Carbon Monoxide Poisoning:

Early signs of carbon monoxide poisoning resemble the 
flu, with headaches, dizziness, or nausea. If you have 
these signs, the heater may not be working properly. 
Get fresh air at once! Have heater serviced. Some 
people are more affected by carbon monoxide than oth

-

ers. These include pregnant women, persons with heart 
or lung disease or anemia, those under the influence of 
alcohol, and those at high altitudes.

Natural Gas:

Raw natural gas is odorless. An odor making agent is 
added to natural gas, which helps you detect a natural 
gas leak. However the odor added to natural gas can 
fade. So natural gas may be present even though no 
odor is detected. Make certain you read and under

-

stand all warnings. Keep this manual for reference. It is 
your guide to safe and proper operation of this heater.

Product Features

Figure 1

PRECAUTIONS:

1.  BF-10NG and IR-10NG may be installed in a 

bedroom, but not a bathroom, or any place where a 
strong wind would shut down the appliance.

2.  This heater needs outside ventilation air to run 

properly. The Oxygen Depletion Sensor (ODS) 

safety shutoff system shuts down the heater if not 

enough fresh air is available. See Fresh Air for 
Combustion and Ventilation, page 4.

3.  Keep all air openings in heater clear, free of debris 

or any blockage. This will insure that enough air for 
proper combustion enters the heater.

4.  If heater shuts off, do not relight until you provide 

fresh, outside air. If heater keeps shutting off, it 
requires servicing.

5.  Turn off and let cool before servicing. Only a 

qualified service person should service and repair 
heater.

6.  Do not run heater:

•  Where flammable liquids or vapors are used or stored
•  During dusty conditions.

7.  Before using furniture polish, wax, carpet cleaner 

or similar products, turn heater off. If heated the 
vapors from these products may create a white 
powder residue within burner box or on adjacent 
walls or furniture.

8.  Do not use heater if any part has been underwater. 

Immediately call a qualified service technician to 
inspect the room heater and to replace any part of 
the control system and any gas control which has 
been underwater.

9.  Operating heater above elevations of 4,500 feet 

could cause pilot/ODS to shutdown heater.

10.  Always run heater with control knob in a locked po

-

sition. Never set control knob between locked posi

-

tions. Poor combustion and higher levels of carbon 
monoxide may result if control knob is left between 
locked positions.

Control Knob

Grill

Front Panel

Burners

Heater 
Cabinet

SPECIFICATIONS

IR10NG

BF10NG

BTU (Available) 

10,000 

10,000 

Type of Gas 

Natural Gas Only 

Natural Gas Only 

Ignition 

Piezo 

Piezo 

Pressure Regulator Setting 

4.5 Inches of Water   

4.5 Inches of Water 

Inlet Gas Pressure (Maximum) 

14 Inches of Water 

14 Inches of Water

Inlet Gas Pressure (Minimum) 

7 Inches of Water 

7 Inches of Water 

Burners / Orifice nozzles 

2  

1

Thermostatic Control 

No 

No

Clearances: inches (mm) 

 

 

  Top 

36” (915cm) 

36” (915cm) 

 Sides 

10” (254cm) 

10” (254cm) 

  Floor (min. to top of carpet) 

3” (76cm) 

3” (76cm) 

  Fabric / flammable objects 

36” (915cm) 

36” (915cm) 36” (915cm) 

Содержание HeatStar HSVFB10NG

Страница 1: ...s supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Fresh Air for Combustion and Ventilation section on page 4 of this manual WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual...

Страница 2: ... Do not place clothing or other flammable material on or near the appliance Never place any objects on the heater Due to high temperatures heater should be kept out of traffic and away from furniture and draperies Surface of heater becomes very hot when running Keep children and adults away from hot surfaces to avoid burns or clothing igni tion Heater will remain hot for a time after shutdown Allo...

Страница 3: ... the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liquids or vapors are used or stored During dusty conditions 7 Before using furniture polish wax carpet cleaner or similar...

Страница 4: ...uction provide adequate combustion and ventila tion air by the methods described in the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 or applicable local codes 3 Add the Btu hr of all the fuel burning appliances in the space such as Vent free heater Gas water SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sen sor ODS safety shut off system The ODS pilot shuts off the heate...

Страница 5: ... space because the actual Btu hr used is more than the maximum Btu hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet and the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add venti lation grills between the rooms See Ventilation Air From Inside Building Fig 2 B Vent room direct...

Страница 6: ...arage Heater pilot and burner must be at least 18 inches above floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Install ing heater next to vinyl or cloth wall covering or operat ing heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc ar...

Страница 7: ...screws until mounting bracket is firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall ar eas between studs or solid walls concrete or masonry Note Wall anchors mounting screws and spacer are in hardware package The hardware package is provided with heater 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete or m...

Страница 8: ...es WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator Use of floor mounting feet will require you to use a 3 8 NPT street elbow to make gas connection CAUTION Never connect heater to private non utility gas well This gas is commonly known as well head gas IMPORTANT Check your gas line pressure before connecting heater to gas line Gas line pres...

Страница 9: ...cked for leaks in next section Low Pressure Test Pressure Equal To or Less Than psig 3 5 kPa 1 Close equipment shutoff valve see figure 13 2 Pressurize supply piping system by either using compressed air or opening main gas valve on or near gas meter 3 Check all joints from the gas meter to equip ment shutoff valve see figure 14 Apply mixture of liquid soap and water to gas joints Bubbles forming ...

Страница 10: ...P Follow B in the safety information above If you do not smell gas go to the next step 5 Push in gas control know slightly and turn counterclockwise to PILOT IGN and depress for five 5 seconds Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for about 30 seconds This will allow air to bleed from the gas system 6 Push in control kn...

Страница 11: ... AND BURNER Use as vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This ca...

Страница 12: ...7 Replace Control valve Burner does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Clean burner orifice see Cleaning and Maintenance on page 11 or replace burner orifice 2 Replace burner orifice 3 Contact local gas company Delayed ignition of burner 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contac...

Страница 13: ... Gas Con nections page 9 2 Replace control valve Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See WARNING statement at top of page 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Con nections page 9 Heater produces a clicking ticking noise just after burner is lit or shut off 1 Metal expanding while heatin...

Страница 14: ...ural Gas Fired Room Heater UNVENTED NATURAL GAS FIRED ROOM HEATER Model IR10NG BF10NG Model IR10NG Model BF10NG 19 23 7 8 21 22 13 1 4 1 2 1 3 6 15 14 28 5 20 16 2 17 4 30 3 1 1 16 18 27 26 25 24 29 19 1 2 1 3 21 2 22 5 10 13 3 23 8 6 30 7 1 4 1 1 28 10 9 11 12 ...

Страница 15: ...13 70338 70338 Pressure regulator 1 14 70326 Glass 1 15 70327 Glass Mounting Bracket 1 16 70365 70365 ODS Pilot Assembly 1 17 70826 Bracket Burner Mtg Blue Flame Vent Free 1 18 70655 ODS mounting bracket 1 19 70396 70396 Heat Shield Top 1 20 70331 Heat Shield Back 1 21 70663 70663 Regulator Mounting Bracket 1 22 70665 70665 Floor mount feet 2 23 70898 70898 Guard VF Wire 10K 1 24 70336 Bracket Top...

Страница 16: ...e of purchase and description of problem in all communication LIMITED WARRANTY Heatstar by Enerco warrants its heaters and accessories to be free from defects in material and workmanship for a period of 5 years from date of purchase Heatstar by Enerco will repair or replace this product free of charge if it has been proven to be defective within the 5 year period and is returned at customer expens...

Отзывы: