Enerco HeatStar HSVFB10NG Скачать руководство пользователя страница 16

16

Installation Instructions and Owner’s Manual

Unvented Natural Gas Fired Room Heater

Model #  

Start Serial#

HSVFR10NG 

 

EC-55225-14001001

HSVFB10NG 

 

EC-55549-14001001

Heatstar by Enerco reserves the right to make changes at any time, without notice or 
obligation, in colors, specifications, accessories, materials and models.

warnInG:

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS 
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE 
DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE 
AGENCY.  

rePlaCeMenT ParTs OrderInG InFOrMaTIOn:

PurCHasInG: 

Accessories may be purchased at any Mr. Heater local dealer or 

direct from the factory 

FOr InFOrMaTIOn reGardInG serVICe

Please call Toll-Free 866-447-2194
www.heatstarbyenerco.com

Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.

Please include the model number, date of purchase, and description of problem in 
all communication.

lIMITed warranTY

Heatstar by Enerco warrants its heaters and accessories to be free from defects in 
material and workmanship for a period of 5 years from date of purchase. Heatstar 
by Enerco will repair or replace this product free of charge if it has been proven to 
be defective within the 5-year period, and is returned at customer expense with 
proof of purchase to Heatstar by Enerco within the warranty period.

Heatstar by Enerco, 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-916-3000
Mr. Heater is a registered trademarks of Mr. Heater, Inc.
© 2009, Mr. Heater. All rights reserved

ANSI Z21.11.2b - 2010

HSVFR10NG

HSVFB10NG

OpErating instructiOns 
and Owner’s Manual

read InsTruCTIOns CareFullY:

 Read and follow all instructions. Place instructions in a safe 

place for future reference. Do not allow anyone who has not read these instructions to assemble, 
light, adjust or operate the heater.

Model #

PRODUCT REGISTRATION:  Thank you for your purchase.  
Please log in to http://www.egiregistration.com to register your product.

Содержание HeatStar HSVFB10NG

Страница 1: ...s supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Fresh Air for Combustion and Ventilation section on page 4 of this manual WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual...

Страница 2: ... Do not place clothing or other flammable material on or near the appliance Never place any objects on the heater Due to high temperatures heater should be kept out of traffic and away from furniture and draperies Surface of heater becomes very hot when running Keep children and adults away from hot surfaces to avoid burns or clothing igni tion Heater will remain hot for a time after shutdown Allo...

Страница 3: ... the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liquids or vapors are used or stored During dusty conditions 7 Before using furniture polish wax carpet cleaner or similar...

Страница 4: ...uction provide adequate combustion and ventila tion air by the methods described in the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 or applicable local codes 3 Add the Btu hr of all the fuel burning appliances in the space such as Vent free heater Gas water SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sen sor ODS safety shut off system The ODS pilot shuts off the heate...

Страница 5: ... space because the actual Btu hr used is more than the maximum Btu hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet and the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add venti lation grills between the rooms See Ventilation Air From Inside Building Fig 2 B Vent room direct...

Страница 6: ...arage Heater pilot and burner must be at least 18 inches above floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Install ing heater next to vinyl or cloth wall covering or operat ing heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc ar...

Страница 7: ...screws until mounting bracket is firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall ar eas between studs or solid walls concrete or masonry Note Wall anchors mounting screws and spacer are in hardware package The hardware package is provided with heater 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete or m...

Страница 8: ...es WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator Use of floor mounting feet will require you to use a 3 8 NPT street elbow to make gas connection CAUTION Never connect heater to private non utility gas well This gas is commonly known as well head gas IMPORTANT Check your gas line pressure before connecting heater to gas line Gas line pres...

Страница 9: ...cked for leaks in next section Low Pressure Test Pressure Equal To or Less Than psig 3 5 kPa 1 Close equipment shutoff valve see figure 13 2 Pressurize supply piping system by either using compressed air or opening main gas valve on or near gas meter 3 Check all joints from the gas meter to equip ment shutoff valve see figure 14 Apply mixture of liquid soap and water to gas joints Bubbles forming ...

Страница 10: ...P Follow B in the safety information above If you do not smell gas go to the next step 5 Push in gas control know slightly and turn counterclockwise to PILOT IGN and depress for five 5 seconds Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for about 30 seconds This will allow air to bleed from the gas system 6 Push in control kn...

Страница 11: ... AND BURNER Use as vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This ca...

Страница 12: ...7 Replace Control valve Burner does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Clean burner orifice see Cleaning and Maintenance on page 11 or replace burner orifice 2 Replace burner orifice 3 Contact local gas company Delayed ignition of burner 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contac...

Страница 13: ... Gas Con nections page 9 2 Replace control valve Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See WARNING statement at top of page 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Con nections page 9 Heater produces a clicking ticking noise just after burner is lit or shut off 1 Metal expanding while heatin...

Страница 14: ...ural Gas Fired Room Heater UNVENTED NATURAL GAS FIRED ROOM HEATER Model IR10NG BF10NG Model IR10NG Model BF10NG 19 23 7 8 21 22 13 1 4 1 2 1 3 6 15 14 28 5 20 16 2 17 4 30 3 1 1 16 18 27 26 25 24 29 19 1 2 1 3 21 2 22 5 10 13 3 23 8 6 30 7 1 4 1 1 28 10 9 11 12 ...

Страница 15: ...13 70338 70338 Pressure regulator 1 14 70326 Glass 1 15 70327 Glass Mounting Bracket 1 16 70365 70365 ODS Pilot Assembly 1 17 70826 Bracket Burner Mtg Blue Flame Vent Free 1 18 70655 ODS mounting bracket 1 19 70396 70396 Heat Shield Top 1 20 70331 Heat Shield Back 1 21 70663 70663 Regulator Mounting Bracket 1 22 70665 70665 Floor mount feet 2 23 70898 70898 Guard VF Wire 10K 1 24 70336 Bracket Top...

Страница 16: ...e of purchase and description of problem in all communication LIMITED WARRANTY Heatstar by Enerco warrants its heaters and accessories to be free from defects in material and workmanship for a period of 5 years from date of purchase Heatstar by Enerco will repair or replace this product free of charge if it has been proven to be defective within the 5 year period and is returned at customer expens...

Отзывы: