Operating Instructions and Owner’s Manual

Enerco Group, Inc. | Convection Construction Heater

REF. #

ITEM #

Description

Qty

1

M8645

Pilot LP Assemby

1

2

M1591

Hose Ass'y, LP

1

3

M8635

Burner Ring Assembly

1

4

M8636

Ring Shield

1

5

M8637

Fuel Tube Assembly

1

6

M8638

Pilot Tube Assembly

1

7

M2240

Upper Shell

1

8

M8639

Orifice Adapter

1

9

M8640

Bracket, Pilot Mounting

1

10

M8646

Orifice, LP

1

11

M8642

Base

1

12

M4223

Cap

1

13

M6045

Clip, TC

1

14

M6104

TE VAlve

1

15

M6137

Ftg., Elbor Female 1/4 FLRx1/8 FPT

1

16

M6138

Ftg., Elbow Female 1/4 FPTx1/4 FLR 1

17

M8643

Thermocouple

1

18

M6252

POL Excell Flow

1

19

M6256

Regulator

1

REF. #

ITEM #

Description

Qty

20

M8654

Valve, Ball

1

21

M6473

Piezo Ignitor

1

22

M6503

Nut, Hex 1/2-28 TE Valve

1

23

M7172

Ftg., Elbow Female 1/4 FPTx3/8 FLR 2

24

M8162

External Retaining Ring

1

25

M7161

Piezo Nut

1

26

M7652

Electrode w/7" Wire

1

27

M4293

Heat Shield

1

28

M8647

Pilot Orifice

1

29

M6689

Washer, Flat 9/16 SAE

1

30

M8187

Fitting, Elbow 1/8 FPTx1/4 CPSN

1

31

M2238

Lower Shell

1

*

M70486

Manual, Operating Instructions

1

*

M8758

Label, Safety Precautions

1

*

M8759

Label, Safety Precautions

1

*

M8757

Label, Installation

1

*

M8756

Label, Model

1

*

M8502

Label, Warning

1

*

M8679-200

BTU

1

*

M8204

Hang Tag

1

*

M8651

Ball Valve knob

1

*

M8655

Ball Valve Knob Insert

1

*Items not shown on exploded view

(80CV ONLY)

(200CV ONLY)

31

Convection Construction Heater • Model 200CV

Содержание HEATSTAR HS200CV

Страница 1: ...may result causing property damage personal injury or loss of life WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylin...

Страница 2: ...STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING WARNING COMBUSTION BY PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER A...

Страница 3: ...Toperatea damagedheater 2 DO NOT modify the heater or operate a heater which has beenmodifiedfromitsoriginalcondition 3 DONOTlightoroperateheaterunlesstheshellsarefully extendedandlockedintoposition S...

Страница 4: ...person and the firefighters check for escaped gas Have them air out the building and area before you return Properly trained service people must repair any leaks check for further leakages and then re...

Страница 5: ...IS HAPPENS THE SCREW HOLES WILL LINE UP STEP 4 LOCK THE CLIP INTO PLACE WITH 3 SCREWS AS SHOWN THE HEATER MUST NOT BE OPERATED UNLESS THE OUTER SHELL IS PROPERLY EXTENDED AND FULLY LOCKED INTO PLACE C...

Страница 6: ...e heater is working properly The flame is contained within the heater The flame is essentially blue with perhaps some yellow tipping There is no strong disagreeable odor eye burning or other physical...

Страница 7: ...proximate size of the cylinder required for these heaters To use the chart 1 Select the lowest air temperature expected at the bottom of the chart 2 Move straight up to time of operation desired left...

Страница 8: ...PTx1 4 MPT 1 M8018 Fitting Adapter 1 8 FPT x 1 4 MPT 1 70486 Manual Operating Instructions 1 REF ITEM Description Qty 19 M6255 Regulator 1 20 M8654 Valve Ball 1 21 M6473 Piezo Ignitor 1 22 M6503 Nut H...

Страница 9: ...Excell Flow 1 19 M6256 Regulator 1 REF ITEM Description Qty 20 M8654 Valve Ball 1 21 M6473 Piezo Ignitor 1 22 M6503 Nut Hex 1 2 28 TE Valve 1 23 M7172 Ftg Elbow Female 1 4 FPTx3 8 FLR 2 24 M8162 Exte...

Страница 10: ...ed our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular purp...

Отзывы: