3
operating Instructions and owner’s Manual
eNeRCo GRoUP, INC. |Indirect Fired Portable Heater
tecHnical speciFicatiOns
MH 1000id
Hs 1000id
MH 2000id
Hs 2000id
MH 3000id
Hs 3000id
Hs 4000id
Heat input
[kBTU/h]
110
205
300
400
Air flow
[cfm]
880
1,530
2,500
2,760
Fuel Type
Diesel/Kerosene/#1-2 Fuel Oil
Heat output
[kBTU/h]
91.9
174.9
254.4
335.6
Fuel consumption
[gal/h]
0.80
1.48
2.28
2.82
[lb/h]
5.53
10.35
15.07
20.07
Power supply
Phase
1
1
1
1
Voltage
[V]
120
120
120
120
Frequency
[Hz]
60
60
60
60
electric consumption
[W]
520
785
1.240
1.440
[A]
5.76
8.30
11.40
13.20
Nozzle
[USgal/h]
0.60-80° S
1.00-45° W
1.20-45° W
1.50-45° W
Pump pressure
[psi]
167
P1: 137
P1: 160
P1: 203
P2: 239
P2: 350
P2: 348
Max static pressure
[in WC]
0.5
0.5
0.5
0.5
Recommended max. temp. in the air
duct
[°F]
250
250
250
250
Adjustment of combustion air flap
[in]
a=0.32
-
-
-
N°
-
A=1.02
A=1.50
B=1.14
Flue diameter
[in]
5.9
5.9
5.9
5.9
Compulsory flue draft
[in WC]
0.05
0.05
0.05
0.05
Tank capacity
[gal]
10.8
17.2
27.7
35.7
Dimensions, l x W x H
[in]
49.3x20.0x30.5
56.5x23.2x37.60
68.5x27.6x37.7
66.3x27.6x45.6
Net Weight
[lb]
94
176
264
330
iMpOrtant
Before using the heater, read and understand all instructions and
follow them carefully. The manufacturer is not responsible for
damages to goods or persons due to improper use of units.
general recOMMendatiOns
This indirect-fired heater runs on diesel fuel. Those with direct
combustion send hot air and the combustion products into
the room, while those with indirect combustion are fitted
with a flue to take the fumes away through the chimney.
Always follow local ordinances and codes when using this
heater:
• Read and follow this owner’s manual before using the
heater.
• Use only in places free of flammable vapors or high dust
content.
• Never use heater in immediate proximity of flammable
materials (the minimum distance must be 6 ft.).
• Make sure fire fighting equipment is readily available.
• Make sure sufficient fresh outside air is provided according
to the heater requirements. Direct combustion heaters
should only be used in well vented areas in order to avoid
carbon monoxide poisoning.
• The heater is installed near a chimney to take away the
fumes (see “Ventilation” on page 5) and connected to an
electrical switchboard.
• When the heater is connected to a flue pipe, the flue pipe
shall terminate in a vertical section at least two feet long
and sufficient draft shall be created to assure safe and
proper operation of the heater.
• Never block air inlet (rear) or air outlet (front).
• In case of very low temperatures add kerosene to the
heating oil.
• Make sure heater is always under surveillance and keep
children and animals away from it;
• Before starting the heater always check free rotation of
ventilator fan.
• Indirect fired units only can be connected to air ducts to
distribute warm air, with respect to the max. static pressure
declared (see “TeCHNICAl SPeCIFICATIoN” sheet).
• Unplug heater when not in use.
Содержание 2000ID
Страница 10: ...10...
Страница 11: ...11...
Страница 12: ...12...
Страница 13: ...13...
Страница 14: ...13A...
Страница 15: ...13B...
Страница 16: ...14...
Страница 17: ...15...
Страница 18: ...16...
Страница 20: ......
Страница 21: ......
Страница 23: ...16...
Страница 24: ...15...
Страница 25: ...14...
Страница 26: ...13B...
Страница 27: ...13A...
Страница 28: ...13...
Страница 29: ...12...
Страница 30: ...11...
Страница 31: ...10...