Eneo VTD-1 Скачать руководство пользователя страница 15

6.0 PC Dialog 

 

- 15 - 

Operating Instructions Text Display 

 

   

 

 

 

 

 
6.2 Text entry 

Allows the editing of on screen text within the raster of 11 rows and 28 column:  

All characters shown in the character 
table (see appendix) can be entered on 
each free position. A white character 
background identifies the current position 
of entry. The cursor position can be 
moved in all four directions by the arrow 
keys. The character entry works 
exclusive in the overwrite mode: 
Characters on the current cursor position 
are overwritten by entry of new 
characters. Wrong characters on the left 
side of the cursor can be deleted  by 

Backspace

’ . 

 

Additional the positions of time and date  – if activated (see below)  – are shown 
coloured in the raster . 
The display of the on screen text appears after power-on reset durable.  
By reception of protocol data the insertion of the defined data fields  (see p.16) 
completes the on screen text. After time-out of the 

text insert

-timer the on screen text 

will be generated anew.  

 
 
6.3 Time / Date 

Date and time display is directly configurable on the main 
menu as follow: 
 
 

§ 

Date:

 Activation/deactivation of date display. If activated a coloured background 

is displayed on the date position. For positioning click with the left mouse button 
on the date field (field appears green) and move the field to the right position  by 
pressed mouse button. After releasing the left mouse button the new position is 
confirmed. 

  

§ 

Time:

  Activation/deactivation of current time display. The configuration is 

performed as described in 

‘Date’

  

§ 

Automatic Switch Summer-/Winter time:

 Controls the function of automatic 

switching between  summer and winter time. If this function is activated  on last 
Sunday of March (begin of summertime) at 02.

00

 the  clock will be set to 03.

00

 

automatically. The reset (3.

00 

º

 2.

00

) will be executed on the last Sunday of 

October. 
 
Note: The automatic switch  will also be set subsequently, if the unit was turned 
off at switching time. 

 
 
 

  

Содержание VTD-1

Страница 1: ...ng instructions Text Display VTD 1 VIDEOR TECHNICAL E Harting GmbH Maybachstra e 5 D 63319 R dermark Germany Phone 0 60 74 8 88 0 Fax 0 60 74 8 88 100 e mail info videortechnical com www videortechnic...

Страница 2: ...n screen text 9 5 3 Timer Keyboard Zoom 10 Relay Timer 10 Data Timer 10 Keyboard Layout 10 Zoom Factor 10 5 4 RS232 Parameters 10 6 0 PC Dialog 11 6 1 Menu 12 Open File Close File 12 Configure PC Inte...

Страница 3: ...600 and the number of colors should be set to True Color To install the program from the included CD ROM run Setup exe in the TD folder Follow the program instructions and install the TD setup in the...

Страница 4: ...e output 2 status LED Connector for PS 2 keyboard Programing Setup Memory Firmware and setup programming via RS232 interface On screen camera text stored in EEPROM Flash memory Housing Metal 140x35x77...

Страница 5: ...Assignment RS232 9 pin D SUB male connector 1 NC 2 RXD 3 TXD 4 NC 5 GND 6 NC 7 RTS 8 CTS 9 NC Relay 3 pole terminal block 1 Relay common 2 Relay make contact 3 Relay break contact NC Not connected DC...

Страница 6: ...meaning and configuration of the parameter describes chapter 5 The general parameters of the interface control are easy to configure by the keyboard Only the modification and positioning of data field...

Страница 7: ...nit now operates with the new parameters independently from the PC The setup data can also be stored on hard disk diskette Thus it is possible to transfer standardized settings without great effort to...

Страница 8: ...een texts Timer Keyboard Zoom Definition of relay time out and insert time by protocol data keyboard layout and modify of character size RS232 Parameters Definition of interface parameters Setup End S...

Страница 9: ...be executed on the last Sunday of October Note The automatic switch will also be set subsequently if the unit was turned off at switching time 5 2 Entry of on screen text Calling up this submenu the u...

Страница 10: ...ggerd by protocol data Data Defines the time the text insertion of protocol data is active range from 1 to 99 seconds NOTE If the relay timer and data timer after a data reception are active and the u...

Страница 11: ...ubmenu Baud Rate Defines the serial data rate in the range from 1200 115 200 baud Data Format The following data formats are supported 8 Data bits no parity 7 Data bits odd parity 7 Data bits even par...

Страница 12: ...llowing pages describe the individual setup functions 6 1 Menu Menu bar Includes the functions for PC and TD that are explained in the following Open save file Open Loads a setup configuration previou...

Страница 13: ...y receiving protocol data Text insert Defines the time the text insertion of protocol data is active in the range from 1 255 seconds By displaying protocol data the timer starts and after time out all...

Страница 14: ...ill be connected to the TD The programming of the text display via PC is fixed on 57 600 baud and will be identified automaticly Program Programming of the text display with the current configuration...

Страница 15: ...16 completes the on screen text After time out of the text insert timer the on screen text will be generated anew 6 3 Time Date Date and time display is directly configurable on the main menu as foll...

Страница 16: ...layed with white background in according to their position The positioning of the fields can be changed by PC mouse as described in date see page 15 On the left hand of the field indentifier you can a...

Страница 17: ...32 O 4F o 6F 3 33 P 50 p 70 4 34 Q 51 q 71 5 35 R 52 r 72 6 36 S 53 s 73 7 37 T 54 t 74 8 38 U 55 u 75 9 39 V 56 v 76 3A W 57 w 77 7 3C X 58 x 78 3D Y 59 y 79 8 3E Z 5A z 7A 3F 60 C4 A 41 A 61 D6 B 4...

Страница 18: ...fications 1 Keep the device away from heat sources and direct sun light 2 Protect the device and the power supply from moisture to avoid the risk of electricall shock and fire 3 If fluids have penetra...