Eneo EPS-1016 Скачать руководство пользователя страница 7

Hardware Description 

This section mainly describes the hardware of the 8 PoE port Ethernet Combo 

Web-Smart Switch and gives a physical and functional overview on the certain 

switch. 

Physical Dimensions/ Weight 

44 × 440 × 220 mm (H × W ×D) / 3.0kg 

Front Panel 

The front panel of the web smart switch consists of 16 10/100Base-TX RJ-45 

ports and 2 combo gigabit uplink RJ-45/SFP ports. The LED Indicators are 

also located on the front panel. 

 

 

 

LED Indicators 

The LED Indicators present real-time information of systematic operation 

status. The following table provides description of LED status and their 

meaning. 

LED 

Status 

Description 

No. Of LED 

Power 

On 

Power on 

Power 

1000M 

On 

Link 1000Mbps 

2 (17~18) 

off 

Link 10/100Mbps 

Link/ ACT 

On 

Link   

18 (1~18) 

Flashing 

Data activating 

18 (1~18) 

PoE 

On 

Port is linked to Power 

Device 

16 (1~16) 

Off 

No Power Device is 

connected 

16 (1~16) 

LED 

Display 

Combo Uplink 

RJ-45/SFP Port 

RJ-45 Port 

 

Содержание EPS-1016

Страница 1: ...Full Manual PoE Switch 16 Ports 10 100Base TX PoE RJ45 and SFP Gigabit Uplink 250W EPS 1016...

Страница 2: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Страница 3: ...ction 2 Hardware Description 5 User Log In 7 Administrator 8 Port Management 13 VLAN Setting 17 Per Port Counter 21 QoS Setting 22 Security 24 Spanning Tree 26 Trunking 29 Backup Recovery 30 Miscellan...

Страница 4: ...ter traffic management reduces latency improve security and save bandwidth This is also a cost saving feature as it reduces the need to add additional hardware to the network These 16 10 100Mbps RJ 45...

Страница 5: ...Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1x Port based Network Access Control IEEE 802 1Q VLAN IEEE 802 1p Class of Service Number of Port 16 port 10 100BaseTX with PoE...

Страница 6: ...75Mb Transmission Method Store and Forward Package Contents Before you start to install this switch please verify your package that contains the following items One Fast Ethernet PoE Switch One EU Po...

Страница 7: ...link RJ 45 SFP ports The LED Indicators are also located on the front panel LED Indicators The LED Indicators present real time information of systematic operation status The following table provides...

Страница 8: ...on a large flat space with a power socket close by The flat space should be clean smooth level and sturdy Make sure there is enough clearance around the switch to allow attachment of cables power cor...

Страница 9: ...e web browser and go to 192 168 2 1 site then the user will see the login screen Key in the password to pass the authentication then clicks the OK The log in process is completed and comes out the sig...

Страница 10: ...ncluding the current IP address and sub net mask and gateway Figure 2 2 User can configure the IP settings Subnet Mask Gateway as below IP address Manually assign the IP address that the network is us...

Страница 11: ...o 15 characters in the Comment Contact and Location field for note Figure 2 3 MAC Address Displays the unique hardware address assigned by manufacturer default Number of Ports Displays number of ports...

Страница 12: ...described as following The purpose of this function is to provide a method for the network administrator to restore all configurations to the default value 1 To activate this function the user should...

Страница 13: ...mechanism in the Boot Loader so the Boot Loader will keep intact Even though the power is turned off or the cable link fails during the firmware update procedure the Boot loader will restore the code...

Страница 14: ...Reboot Device Click Confirm button to reboot the device Figure 2 7 Note The reboot is for software base instead of hardware base 12...

Страница 15: ...d to the ports ticked Duplex When the Auto Negotiation column is set as Disable users have to set the connection mode in Half Full to the ports ticked Pause Flow Control for connection at speed of 10...

Страница 16: ...LAN analyzer or Netxray Monitored Packets Pull down the selection menu to choose what kind of packet is to be monitored Source Port The ports that the user wants to monitor All monitored port traffic...

Страница 17: ...port and the number of broadcast packets is counted in every time unit One time unit is 500 us for 10Mbps speed and 5ms for 100Mbps The excessive broadcast packet will be discarded For those broadcast...

Страница 18: ...Click Update to have the configuration take effect PoE User could know per PoE port out power status in this page and also enable or disable per port Figure 3 5 16...

Страница 19: ...le switch There is no handover of network traffic within VLAN groups to other switches For the handover to other switches use Tag Based VLAN In VLAN Mode you can switch from Tag to Port Based VLAN Por...

Страница 20: ...here looks different whether you run Tag Based or Port Based Mode VLAN Member in Port Based Mode Figure 4 3 In Port Based Mode you see a matrix of your 8 Ports Simply select the port on top screen yo...

Страница 21: ...right of VID Setting then select or deselect which ports are member of that group Your up and downlink ports need to member of every existing group Then click on add The new group with its setting wil...

Страница 22: ...Setting When VLAN member Setting is updated multi to 1 setting will be void and vice versa The disable port means the port which will be excluded in this setting All ports excluded in this setting ar...

Страница 23: ...ived packet count excluding the incorrect packet and the transmitted packet count Collision Count Transmit packet This category shows the packets outgoing from the switch and the count of collision Dr...

Страница 24: ...ify such classes but they do not guarantee delivery as do quality of service QoS functions which are implemented in the network devices Priority Mode There are three priority modes available to specif...

Страница 25: ...Port 802 1p IP DS based Figure 6 2 TCP UDP Port Based 23...

Страница 26: ...rt Read Pull down the selection bar to choose a port number and click the read button to show the MAC addresses bound with the port or modify the MAC addresses Select Port Pull down the selection menu...

Страница 27: ...096 Therefore there are 16 distinct values Hello Time Interval in seconds at which the root device transmits a configuration message BPDU frame Number between 1 10 default is 2 Max Age The maximum tim...

Страница 28: ...ween devices Therefore lower values should be assigned to ports attached to faster media and higher values assigned to ports with slower media Set the RSTP path cost on the port Number between 0 20000...

Страница 29: ...Loopback Detection Settings Figure 8 3 27...

Страница 30: ...e trunk group causes the network traffic to be directed to the remaining ports Load balancing is maintained whenever a link in a trunk is lost or returned to service This switch may use Port ID Source...

Страница 31: ...guration The user can save configuration file to a specified file If the user wants to recover the original configuration which is saved at the specified path just enter the password and then press th...

Страница 32: ...a useless packet To prevent these packets from wasting the bandwidth this switch provide an option for the administrator to enable the queue aging function VLAN Striding By selecting this function th...

Страница 33: ...t setting Please take the following steps to reset the Web Smart Switch back to the original default Step 1 Turn on the Web Smart Switch Step 2 Press and hold the reset button continuously for 5 secon...

Страница 34: ...Password admin 32...

Страница 35: ......

Страница 36: ...istribution through specialised trade chan nels only Videor E Hartig GmbH Carl Zeiss Stra e 8 63322 R dermark Germany Tel 49 0 6074 888 0 Fax 49 0 6074 888 100 www videor com www eneo security com Tec...