15
5.2.4.
Mixer
Package:
-
1 pc Mixer with motor
-
4 pcs Screw M12
-
1 pc Gasket
Special tools required: 32 mm drill
Installation process
The mixer shall be installed at the
top of the tank. Drill an opening by
the drill bit of 32 mm diameter, the
center is marked. Place the gasket
between the tank body and the
mixer’s flange. Tighten the flange to
the separator body with 4 bolts. Do
not apply too much force.
Figure 12. Fitting of Mixer
5.2.5. Grease alarm
Package:
-
1 pc grease alarm type GA-1 (panel and sensor)
-
2 pcs bracket for the alarm unit
-
2 pcs screws M6 & 4 pcs screws M4
Installation process
The grease alarm panel is to be fitted to the bracket which is attached to the separator body.
Tighten two metal brackets to the housing by 2 screws M6 provided. Fit the panel to the
brackets by 4 crews M4.
Drill a ø12 mm opening for the sensor cable on the top of the separator body in the area as
indicated in figure 13. Route the cable through the cable duct. Screw the cable duct to the
separator wall. The sensor is to be suspended at the height of 150 mm below the static water
level i.e. the bottom of the outlet nozzle.
Electrical connections of Grease alarm shall be installed according to figure 13.
Содержание Greasly-2A
Страница 18: ...18 Figure 15 Wiring diagram...