6
Charging A Battery
(continued)
7. The CHG LED will illuminate GREEN with no flashing when the battery
is fully charged.
8. After removing a fully charged battery, the CHG LED will illuminate
ORANGE for a few seconds. Allow the CHG LED to go off before placing
another battery in the charging pod.
9. The EC1C-BK2 is designed to charge batteries with a temperature
monitoring circuit when the battery temperature is between 0°C and
45°C (32° F – 113° F); batteries outside this temperature will not be
charged. When charging a battery, the ambient temperature should
be 5°C - 40°C (41° F - 104° F).