S P E C I F I C A T I O N S
Network I/O (Option):
Rear-panel RJ-45 jack.
10/100Base-T ethernet.
Supported IPv4 Network Protocols (Option):
TCP/IP
SSH
Telnet
DHCP
SNMP v1 and v2 with community strings. Limited implementation - MIB-II only.
AC Power:
90-132 VAC/180-264 VAC, 47-63 Hz, 0.6 A Max. @ 120 VAC, 0.3 A Max. @ 240 VAC.
3-Pin IEC 320 on rear panel, 2 meter line cord is included.
DC Power (Option):
12 VDC (10-20 VDC), 5A maximum.
24 VDC (19-36 VDC), 2.5A maximum.
48 VDC (38-72 VDC), 1.5A maximum.
125 VDC (70-160 VDC), 0.75A maximum.
3-position terminal block on rear panel: +DC IN, SAFETY GROUND, -DC IN.
(Floating power input: Either “+” or “-” can be connected to earth ground.)
Size:
Chassis: 1.75”H x 17.0”W x 10.75”D.
Weight: < 5 lb. (2.70 kg.).
Environmental:
Operating Temperature:
0° to +50° C
Storage Temperature:
-40° to +85° C
Antenna Operating Temperature:
-40° to +85° C
Operating Humidity:
5% to 90%, RH, non-condensing
Storage Humidity:
5% to 95%, RH, non-condensing
Maximum Operating Altitude:
AC:
13,125 ft. / 4000 meters
12/24 VDC:
13,125 ft. / 4000 meters
48 VDC (<61 VDC Max.): 13,125 ft. / 4000 meters
48 VDC (>60 VDC Max): 6,562 ft. / 2000 meters
125 VDC:
6,562 ft. / 2000 meters
Compliance:
CE, FCC, RoHS, WEEE.
Содержание FDC3302
Страница 2: ......
Страница 6: ...F D C 3 3 0 2 U s e r M a n u a l...
Страница 10: ...F D C 3 3 0 2 U s e r M a n u a l...
Страница 13: ...3 F D C 3 3 0 2 U s e r M a n u a l...
Страница 14: ...F D C 3 3 0 2 U s e r M a n u a l 4 C H A P T E R O N E...
Страница 40: ...F D C 3 3 0 2 U s e r M a n u a l 30 A P P E N D I X D EndRun EndRun EndRun EndRun FDC3302 DIMENSIONS AC POWER...
Страница 41: ...31 F D C 3 3 0 2 U s e r M a n u a l S P E C I F I C AT I O N S...
Страница 42: ...F D C 3 3 0 2 U s e r M a n u a l 32 A P P E N D I X D...
Страница 44: ...F D C 3 3 0 2 U s e r M a n u a l 34 S P E C I A L M O D I F I C AT I O N S...
Страница 45: ......