C O N T R O L A N D S T A T U S C O M M A N D S
supply). A one ‘1’ means the power supply is good. An ‘x’ means the optional power supply is not
installed.
Query:
pwrstat
Chassis response:
1x
(The first supply (Power A) is good. The second
supply (Power B) is not installed.
reset
This command will cause a software reset.
Command:
reset
Chassis response:
OK
(The chassis will reset.)
respmode
This command configures the way the chassis responds to commands. If you change this setting it
will be saved in non-volatile memory. Command syntax is: respmode = x, where x is either TERSE
or VERBOSE. The TERSE mode means that when a command is entered the chassis will respond
with only data. The VERBOSE mode means that when a command is entered the chassis will re-
spond with the command name and equal sign followed by the data (for example:
ratea=1000
).
Set:
respmode=verbose
Chassis response:
OK
(The chassis will respond to all future commands and
queries by including the command name.)
Query:
respmode
Chassis response:
terse
or
Query:
respmode
Chassis response:
respmode=verbose
Factory default setting:
terse
return
After the chassis has switched from the primary to the secondary signal input, this command is used
to return to the primary input. After you have restored the signal on primary input, type
return
to
force the chassis to switch back to primary. An alternate way to force the chassis to switch back to
the primary input is by removing the secondary disable input (provided that
disablemode
has been
configured properly). It is also possible to accomplish the return by physically disconnecting the
secondary input momentarily. However this will cause a brief interruption in the output signal during
the switch. For this reason, using
return
or the disable input are the preferred methods.
This command is also used after the chassis has switched from the primary signal input to no signal
input (
selectedin=NONE
). This will occur if
disablemode
has been configured to allow it. If the
selected input is NONE then correct the problem and enter the
return
command to restore the unit
to proper operation.
Содержание FDC3302
Страница 2: ......
Страница 6: ...F D C 3 3 0 2 U s e r M a n u a l...
Страница 10: ...F D C 3 3 0 2 U s e r M a n u a l...
Страница 13: ...3 F D C 3 3 0 2 U s e r M a n u a l...
Страница 14: ...F D C 3 3 0 2 U s e r M a n u a l 4 C H A P T E R O N E...
Страница 40: ...F D C 3 3 0 2 U s e r M a n u a l 30 A P P E N D I X D EndRun EndRun EndRun EndRun FDC3302 DIMENSIONS AC POWER...
Страница 41: ...31 F D C 3 3 0 2 U s e r M a n u a l S P E C I F I C AT I O N S...
Страница 42: ...F D C 3 3 0 2 U s e r M a n u a l 32 A P P E N D I X D...
Страница 44: ...F D C 3 3 0 2 U s e r M a n u a l 34 S P E C I A L M O D I F I C AT I O N S...
Страница 45: ......