F D C 3 3 0 0   U s e r   M a n u a l

F D C 3 3 0 0   U s e r   M a n u a l

Содержание FDC3300

Страница 1: ...Smarter Timing Solutions FDC3300 Frequency Distribution Chassis User Manual...

Страница 2: ......

Страница 3: ...d refinement of the technologies required to fulfill the demanding needs of the time and frequency community The instruments produced by EndRun Technologies have been selected as the timing reference...

Страница 4: ...ndRun Technologies Buyer shall prepay shipping charges to EndRun Technologies and EndRun Technologies shall pay shipping charges to return the product to Buyer However Buyer shall pay all shipping cha...

Страница 5: ...agent It is important to contact us first as many prob lems may be resolved with a phone call Please have the serial number of the unit and the nature of the problem available before you call If it is...

Страница 6: ...F D C 3 3 0 0 U s e r M a n u a l...

Страница 7: ...e Introduction 1 Main Features 1 Overview 1 Performance Reliability and Reasonable Cost 1 Flexibility 1 Easy Installation 1 Free FLASH Upgrades 2 Theory of Operation 2 Overview 2 Chapter Two Basic Ins...

Страница 8: ...rt 12 pwrstat 12 reset 12 respmode 12 return 13 selectedin 13 settings 13 siginstat 14 sigoutstat 14 status 14 switchmode 14 upload 15 ver 15 RS 232 Serial I O Port Signal Definitions 15 Appendix A LE...

Страница 9: ...ser Commands 21 Detailed Command Descriptions 22 netconfig 22 netmac 22 netpass 22 netprotocol 23 netreset 23 netsnmp 23 netsnmpro 23 netsnmprw 24 Upgrading Firmware 24 What You Need To Perform the Up...

Страница 10: ...F D C 3 3 0 0 U s e r M a n u a l...

Страница 11: ...dundant power supply capabilities high availability signal distribution systems for top tier commercial and military applications may be efficiently implemented The unit will accept a TTL or Open Coll...

Страница 12: ...disable inputs are monitored to allow switching based on the alarm output from the upstream signal source This external alarm signal can be connected to rear panel BNC connectors labeled DISABLE IN T...

Страница 13: ...vel Detect Signal Amp Output Level Detect Signal Amp Output Level Detect Signal Amp Output Level Detect Signal Amp Output Level Detect Signal Amp Output Level Detect Output 1 Output 2 Output 3 Output...

Страница 14: ...F D C 3 3 0 0 U s e r M a n u a l 4 C H A P T E R O N E...

Страница 15: ...t Checking and Identifying the Hardware Unpack and check all the items using the shipment packing list Contact the factory if anything is missing or damaged The FDC3300 shipment typically contains FDC...

Страница 16: ...LY TORQUE TO 9 in RS 232 OUT 1 2 3 4 5 6 7 8 9 10 SIGNAL IN DISABLE IN ALARM OUT 10 100Base T A B SIGNAL IN DISABLE IN 100 240V 0 5A 50 60 Hz 48V 1 5A 00 D0 C9 55 69 FC RS 232 Connector This DB 9M con...

Страница 17: ...manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmul interference in which case the user will be required to corre...

Страница 18: ...signal s to the Signal Input A and or Signal Input B on the FDC3300 The factory default for the FDC3300 switchmode setting is for Signal Input A to be the primary and Signal Input B to be the secondar...

Страница 19: ...es serial port baud rate data bits parity and stop bits pwrstat Prints the current status of the power supplies A 1 means the power supply is operational A 0 means it is not reset This command will ca...

Страница 20: ...utput 3 signal absent FPGA error Disable B asserted Output 4 signal absent Network port error option Power Supply A failed Output 5 signal absent Power Supply B failed option Output 6 signal absent Ou...

Страница 21: ...ut A will be switched off which will turn off all the outputs Once both inputs have been switched off then you must use the return command to restore the unit to a normal operating condition If disabl...

Страница 22: ...only command shows the status of the power supplies and power inputs The distribution chassis is capable of having two power supplies for redundancy but the standard unit has only one The second is a...

Страница 23: ...disable input provided that disablemode has been configured properly It is also possible to accomplish the return by physically disconnecting the secondary input momentarily However this will cause a...

Страница 24: ...selectedin A siginstat 11 sigoutstat 1111111111 switchmode This command sets the switching mode in case a fault is detected A fault is either lack of sig nal presence or a logic high level on Disable...

Страница 25: ...10 0061 000 1 00 Oct 19 2007 10 04 47 FPGA 6020 000x 000 v 86K RS 232 Serial I O Port Signal Definitions The RS 232 DB9M connector on the rear panel of the Distribution Chassis is wired as shown below...

Страница 26: ...F D C 3 3 0 0 U s e r M a n u a l 16 C H A P T E R T H R E E...

Страница 27: ...OLOR MEANING Green The signal input is selected as the current input Red The signal input should be present but it is not See switch mode to determine whether a signal input should be present or not F...

Страница 28: ...ut LEDs COLOR MEANING Green The output is present Red The output is absent shorted or the output driver has failed Alarm LED COLOR MEANING Green No alarm condition exists Red An alarm condition exists...

Страница 29: ...nal program CAUTION You may perform the upload using any of the support serial I O parameter combinations except that 8 data bits must be used You must use 8 data bits because the FLASH image that you...

Страница 30: ...r failure during upload or other accident do not be alarmed Even though you may have lost the existing application program the Distribution Chassis boot loader program will remain intact On boot up it...

Страница 31: ...accept connections on the standard ssh port 22 When log ging in via ssh be prepared to wait for about 30 seconds for the password entry prompt to appear on your terminal A public private RSA key pair...

Страница 32: ...ss 111 222 333 444 or hyphen if you are not using one In the example below the user is disabling DHCP and setting the IP address netmask gateway and the primary DNS address The secondary DNS is not us...

Страница 33: ...are changed For example if you change from DHCP on to off then you will need to reset the network port Command netreset Chassis response Resetting network port netsnmp This command enables or disable...

Страница 34: ...your FDC3300 via Telnet and supports file uploading using protocols XMODEM 128 with CRC or XMODEM 1K with CRC These are very common file transfer protocols and should be supported by virtually any te...

Страница 35: ...loader program will remain intact On boot up it will check to see if a valid application program is in the FLASH memory If there is not it will immediately go into the waiting for download mode sendin...

Страница 36: ...F D C 3 3 0 0 U s e r M a n u a l 26 A P P E N D I X C...

Страница 37: ...rm State TTL high or high Z internal 10k pull up Connectors Rear panel female BNCs labeled Disable In Alarm Output Open collector 40 VDC Max 100 mA Max Saturation Current High Impedance when any fault...

Страница 38: ...VDC 0 5A Max 120 VDC 3 Pin IEC 320 on rear panel 2 meter line cord is included DC Power OPTION 12 24 48 VDC 2 0A Max 12 VDC 3 position terminal block on rear panel DC IN SAFETY GROUND DC IN Floating p...

Страница 39: ......

Страница 40: ...2270 Northpoint Parkway Santa Rosa CA 95407 TEL 1 877 749 3878 FAX 707 573 8619 www endruntechnologies com Smarter Timing Solutions...