Operation
Refuelling
the generator
38
ESE 406 - 606 (D)HG-GT (ES) Duplex
Status: August 2017
Refuelling the generator
Proceed as follows to refuel the generator.
The following requirements must be met:
the device must be shut off.
the device must be cooled down.
there must be an adequate air supply and air removal
Appliances switched off or disconnected
DANGER!
Danger to life and danger from combustions
Leaking engine oil and petrol can ignite or explode on
hot parts of the device.
Prevent leaking of engine oil and petrol.
Never refuel when the engine is running.
Allow device to cool off before refuelling.
Avoid open flames and sparks.
WARNING!
Leaking engine oil can contaminate the soil and ground-
water.
Do not fill the tank completely.
Use a filling aid.
WARNING!
Using the wrong fuel will destroy the engine.
Only refuel with lead-free regular grade petrol RON 95 or
higher.
Refuel the generator as follows:
1.
Unscrew tank cover.
2.
Insert filler aid into the filler neck.
3.
Add petrol.
4.
Remove filler aid.
5.
Screw on tank cap
Requirements
Refuelling the device
Содержание ESE 406 HG-GT ES DUPLEX
Страница 12: ...General information Safety symbols 12 ESE 406 606 D HG GT ES Duplex Status August 2017 Notes...
Страница 53: ...Operation Disposal Status at August 2017 ESE 406 606 D HG GT ES Duplex 53 Notes...
Страница 68: ...Troubleshooting 68 ESE 406 606 D HG GT ES Duplex Status August 2017 Notes...
Страница 71: ...Technical specifications Maintenance work Status at August 2017 ESE 406 606 D HG GT ES Duplex 71 Notes...
Страница 75: ...Written guarantee Status at August 2017 ESE 406 606 D HG GT ES Duplex 75 10 Written guarantee...
Страница 76: ...Written guarantee 76 ESE 406 606 D HG GT ES Duplex Status August 2017...
Страница 77: ...Written guarantee Status at August 2017 ESE 406 606 D HG GT ES Duplex 77 Notes...
Страница 78: ...Proof of maintenance 78 ESE 406 606 D HG GT ES Duplex Status August 2017 11 Proof of maintenance...