22
Charging batteries
Requirements
• Completed warm-up phase
• Switch the ECOtronic switch to the “OFF” position.
The DC connection (Figure 4, No. 12) provides a DC voltage of
12V/8A to charge 12V batteries.
DANGER!
• Explosive hydrogen gas may escape during the charging
process: Make sure that neither sparks nor an open
fi
re may
occur in the vicinity of the battery and the power generator
during the charging process.
• Battery acid may harm the eyes and clothing. Avoid any
contact and proceed with extreme caution.
1. Connect the red positive terminal to the positive (+) terminal
of the battery.
2. Insert the 2-pin connector of the 12V charging cable into the
12V socket (Figure 4, No. 12).
3. Connect the black negative terminal to the negative terminal
of the battery.
✓
Battery is charging