34
Commissioning
Fig. 7-1 Wheel set parts
7.4
Refuelling your generator
Proceed as follows to refill the generator's own tank: the generator.
Requirements:
the generator must be turned off
the generator has cooled down
there must be an adequate air supply and air removal
all power consuming equipment must be disconnected or switched off
DANGER!
Leaking engine oil and fuel can burn or explode.
A risk of suffering severe even deadly burns.
► Prevent engine oil or fuel from leaking out.
► Remove leaked operating fluids immediately and appropriately.
► Never use an additional start aid.
► Smoking, naked flames and sparks are forbidden.
NOTICE!
Leaking fuel can contaminate soil and groundwater.
► Take note of the residual quantity in the tank and its maximum filling capacity.
► Always bear in mind that the fuel gauge reacts only after a time delay.
► Fill the tank to a maximum of 95%.
► Always use a filling aid (e.g. funnel).
Содержание ECO Power Line ESE 3000 BS
Страница 1: ...ECO Power Line Generators TRANSLATION OF THE ORIGINAL OPER ATING MANUAL ESE 3000 BS ESE 6000 BS...
Страница 30: ...30 Description of the device NOTES...
Страница 56: ...56 Replacement parts NOTES...
Страница 57: ...57 Wiring diagram 14 Wiring diagram...
Страница 58: ...58 CE declaration 15 CE declaration...