Proservo
26
Hauser
060
Signal input from field units
0
HART protocol (e.g. NMT, NRF)
1
HART + Pt100 Spot temp.
2
HART + Operation contact, 3digits
3
HART + Pt100 Spot temp.+ Operation contact
4
HART + 1 x status
5
HART + Pt100 Spot temp. + 1 x status
6
HART + Pt100 + Operation c1 x status
9
Special vesion
070
Element spacing
A
Range: 0 -10m, AISI316 wire
B
Range: 0 -16m, AISI316 wire
C
Range: 0 -28m, AISI316 wire
L
Range: 0 -36m, AISI316 wire
G
Range: 0 -10m, AISI316 wire PFA covered wire
H
Range: 0 -16m, AISI316 wire PFA covered wire
J
Range: 0 -10m, Alloy C
K
Range: 0 -16m, Alloy C
Y
Special version
080
Cable entry
E Four thread G(PF)1/2"
F
Four thread G(PF)3/4"
G Four thread NPT1/2"
H Four thread NPT3/4"
J
Four thread PG 16
K Four thread PG 21
L Four thread M20
M Four thread M25
Y Special version
090
Process connection
A Flange JIS10 K 80A RF
C Flange JIS10 K 80A FF
E Flange JIS 20 K 80A RF (only for 25bar drum chamber)
G Flange ANSI 3" 150 Ibs RF
J
Flange ANSI 3" 300 Ibs RF (only for 25bar drum chamber)
U Flange JIS10 K 150A RF
T Flange ANSI 6" 150 Ibs RF
L Flange DIN DN80 PN10 RF
N Flange DIN DN80 PN25 RF (only for 25bar drum chamber)
Q Flange JPI 3" 150 Ibs RF
S Flange JPI 3" 300 Ibs RF (only for 25bar drum chamber)
Y Special version
100
Power supply
3 85 - 264 VAC, 50/60 Hz
4 20 - 62 VDC, 20W/ 20 - 55 VAC, 50/60 Hz, 20VA
9 Special version
110
Displacer shape, diameter, material
B
Conical 50 mm, PTFE
D Cylindrical 50 mm, AISI316 (standard)
K
Cylindrical 40 mm, AISI316
N Cylindrical 30 mm, AISI316
R
70 mm, W&M NMi
S
110 mm, W&M PTB
T
Cylindrical 50 mm, AIloy C
U Cylindrical 50 mm, PTFE
V
Cylindrical 40 mm, PTFE
W Cylindrical 30 mm, PTFE
Y
Special version
NMS5-
product designation (part2)