Brief Operating Instructions

Proline Prosonic Flow 93T Portable

Portable ultrasonic flow measuring system

These Brief Operating Instructions are 

not 

intended to replace the 

Operating Instructions provided in the scope of supply.
Detailed information is provided in the Operating Instructions and 
the additional documentation on the CD-ROM supplied. 

The complete device documentation consists of:
• These Brief Operating Instructions
• Depending on the device version:

– Operating Instructions and the Description of Device Functions
– Approvals and safety certificates
– Special safety instructions in accordance with the approvals for 

the device (e.g. explosion protection, pressure equipment 
directive, etc.)

– Additional device-specific information

Содержание Proline Prosonic Flow 93T Portable

Страница 1: ...s provided in the Operating Instructions and the additional documentation on the CD ROM supplied The complete device documentation consists of These Brief Operating Instructions Depending on the devic...

Страница 2: ...Connecting and switching on the transmitter 8 2 5 Determining the installation distances 9 2 6 Mechanical preparation 11 2 7 Installing Prosonic Flow P DN 15 to 65 to 2 17 2 8 Installing Prosonic Flo...

Страница 3: ...manufacturer is not liable for damage caused by improper or non designated use 1 2 Installation commissioning and operation The measuring device must only be installed connected commissioned and main...

Страница 4: ...ROM is mandatory The device must be wired as specified in the wiring and connection diagrams Interconnection must be permitted When hot fluids pass through the measuring tube the surface temperature...

Страница 5: ...nical Information on the CD ROM Mounting location Correct flow measurement is possible only if the pipe is full Entrained air or gas forming in the pipe can result in an increase in measuring errors F...

Страница 6: ...nd protected against solids buildup Horizontal In the recommended installation range in a horizontal installation position View B gas and air collections at the pipe cover and problematic deposits at...

Страница 7: ...sor well clear of fittings such as valves T pieces elbows etc Compliance with the following inlet and outlet runs is recommended in order to ensure measuring accuracy A0013459 Fig 2 Inlet and outlet r...

Страница 8: ...250 to 4000 10 to 160 2 3 Determining the necessary installation distances The installation distances that are necessary for installation depend on The type of sensor Prosonic Flow P DN 50 to 4000 2 t...

Страница 9: ...f the device 28 1 F Enter the function matrix starting with measured value display 2 P Select the group QUICK SETUP F Confirm selection 3 P Select the SENSOR INSTALLATION function F Confirm selection...

Страница 10: ...ng Home position Quick Setup Setup sensor Language Clamp On Measurement Sensor type 1 or 2 Sensor configuration Number of traverses Pipe standard Nominal diameter Pipe material Sound velocity pipe Pip...

Страница 11: ...ting rail A0013546 Fig 4 Setting the sensor distance with the aid of the mounting rail A Sensor distance for measurement via one traverse B Sensor distance for measurement via two traverses Sensor For...

Страница 12: ...sor holder over the pipe A0013542 Fig 5 Setting the sensor holder on the pipe 3 Release the quick release of the retaining bracket a and push the retaining bracket up against the pipe A0013543 Fig 6 G...

Страница 13: ...Endress Hauser 13 4 Fix the sensor holder in place by Tightening the quick release of the retaining bracket a Tightening the quick release b A0013544 Fig 7 Fixing the sensor holder in place a Quick r...

Страница 14: ...as tight as possible by hand 5 Set the strapping band to the desired position 6 Push down the tensioning screw and tighten the strapping band so that it cannot slip Second strapping band 7 Proceed as...

Страница 15: ...t over the strapping band 4 Wrap the strapping band around the pipe without twisting it 5 Guide the end of the strapping band through the strapping band lock tensioning screw is pushed up 6 Tighten th...

Страница 16: ...the ratchet lock a open push the end through the slot Pretension manually by pulling on the free end of the strapping band Note If you do not pretension the bands it is more difficult to release the s...

Страница 17: ...y mounted 11 The distance of the sensor holder is set sensor distance 11 Material The following material is needed for mounting Sensor Connecting cable Note Prior to mounting connect the connecting ca...

Страница 18: ...ortable 18 Endress Hauser 2 Mount as illustrated in the graphic steps 1 to 5 A0013551 Fig 12 Mounting the sensors This completes the mounting process The sensors can now be connected to the transmitte...

Страница 19: ...ted Two measuring wires each with a cable lug and a fixer to position the strapping bands Two sensor holders Coupling fluid for an acoustic connection between the sensor and pipe Two sensors incl conn...

Страница 20: ...can still be moved 4 Take the still movable strapping band incl the mounting bolt and move it until both measuring wires are evenly tensioned and tighten the strapping band so that it cannot slip A000...

Страница 21: ...es of the sensor with coupling fluid 8 Insert the sensor into the sensor holder 9 Fit the sensor cover on the sensor holder and turn until The sensor cover engages with a click The arrows close are po...

Страница 22: ...ows with bores The bores in one of the rows are indicated by letters and the bores in the other row are indicated by numerical values The value determined for the POSITION SENSOR installation distance...

Страница 23: ...01117 Fig 19 Mounting the sensor holders 5 Coat the contact surfaces of the sensors with an even layer of coupling fluid approx 1 mm 0 04 thick going from the groove through the center to the opposite...

Страница 24: ...transmitter via the connecting cables 25 2 9 Post installation check Are cables or the device damaged visual inspection Does the device correspond to specifications at the measuring point including pr...

Страница 25: ...he charger supplied Other equipment could cause the battery to overheat Compare the information on the nameplate of the charger with the local supply voltage and frequency To charge the storage batter...

Страница 26: ...g device have the same color code Note To ensure correct measuring results route the cable well clear of electrical machines and switching elements A0011480 Fig 22 Transmitter connections 1 On off swi...

Страница 27: ...the onsite display The measuring device starts operating as soon as the startup procedure is complete Various measured values and or status variables appear on the display Note If an error occurs dur...

Страница 28: ...1 Minus key for entering selecting 2 Plus key for entering selecting 3 Enter key for calling the function matrix saving When the keys are pressed simultaneously Esc Exit the function matrix step by st...

Страница 29: ...e group e g CONTROL F Confirm selection 4 P Select the function group e g BASIC CONFIGURATION F Confirm selection 5 N Select function e g LANGUAGE 6 P Enter code 93 only for the first time you access...

Страница 30: ...ioning function settings already made are retained Note Observe the following when performing the Quick Setup Configuration selection Select the ACTUAL SETTING option Unit selection This is not offere...

Страница 31: ...Proline Prosonic Flow 93T Portable Commissioning Endress Hauser 31...

Страница 32: ...KA00034D 06 EN 13 11 71136632 FM SGML 6 0...

Отзывы: