Proline Promag 300 Modbus RS485
Description of device parameters
Hauser
43
User entry
Max. 10-digit string consisting of numbers.
Factory setting
Depends on the software option ordered
Additional information
Description
If a measuring device was ordered with an additional software option, the activation code
is programmed in the device at the factory.
User entry
To activate a software option subsequently, please contact your Hauser sales
organization.
NOTE!
The activation code is linked to the serial number of the measuring device and varies
according to the device and software option.
If an incorrect or invalid code is entered, this results in the loss of software options that
have already been activated.
▸ Before you enter a new activation code, make a note of the current activation code .
▸ Enter the new activation code provided by Hauser when the new software
option was ordered.
▸ Once the activation code has been entered, check if the new software option is displayed
in the
SW option overv.
The new software option is active if it is displayed.
If the new software option is not displayed or all software options have been deleted,
the code entered was either incorrect or invalid.
▸ If the code entered is incorrect or invalid, enter the old activation code .
▸ Have your Hauser sales organization check the new activation code
remembering to specify the serial number or ask for the code again.
Example for a software option
Order code for "Application package", option
EA
"Extended HistoROM"
The software options currently enabled are displayed in the
SW option overv.
Web browser
Once a software option has been activated, the page must be loaded again in the Web
browser.
SW option overv.
Navigation
Expert → System → Administration → SW option overv. (0015)
Description
Displays all the software options that are enabled in the device.
User interface
• Extend. HistoROM
• ECC
• HBT Monitoring
• Custody transfer
• HBT Verification