Proline Cubemass 300 Modbus RS485
Description of device parameters
Hauser
93
Square exp coeff
Navigation
Expert → Sensor → Calculated value → Corr. vol.flow. → Square exp coeff (1818)
Prerequisite
The
Calc ref density
option is selected in the
Corr. vol.flow.
parameter (→ 90)
parameter.
Description
For fluid with a non-linear expansion pattern: use this function to enter a quadratic, fluid-
specific expansion coefficient for calculating the reference density.
User entry
Signed floating-point number
Factory setting
0.0 1/K²
3.2.7
"Sensor adjustment" submenu
Navigation
Expert → Sensor → Sensor adjustm.
‣
Sensor adjustm.
Install. direct. (1809)
‣
Zero point adj.
‣
Variable adjust
Install. direct.
Navigation
Expert → Sensor → Sensor adjustm. → Install. direct. (1809)
Description
Use this function to change the sign of the medium flow direction.
Selection
• In arrow direct.
• Against arrow
Factory setting
In arrow direct.
Additional information
Description
Before changing the sign: ascertain the actual direction of fluid flow with reference to
the direction indicated by the arrow on the sensor nameplate.