background image

Omnigrad S 

-

TR62

Hauser

7

Certificates & approvals

Ex approval 

• ATEX Certificate CESI 05ATEX038 for explosion proof type of protection: ATEX II 2 G EEx-d IIC T6..T5 

T85°...T100°C. The TR62 is 

marked.

• ATEX Certificate KEMA 01ATEX1169 X for intrinsically safe type of protection: 1GD or 1/2 GD EEx-ia IIC 

T6...T1 T85...450°C. The TR62 is 

marked.

With regards to the NAMUR NE 24 certificate and the Manufacturer’s Declaration according to the standard 
EN 50018, EN 50020, EN 50281-1-1, EN 50281-1-2, E+H Customer Service will be able to provide further 
detailed information.

PED approval

The Pressure Equipment Directive (97/23/CE) is respected. As paragraph 2.1 of article 1 is not applicable to
these types of instruments. The 

mark according to PED Directive is not requested.

Material certification 

The material certificate EN 10204 3.1 can be directly selected from the sale structure of the product and refers
to the parts of the sensor in contact with the process fluid.
Other types of certificates related to materials can be requested separately.
The “short form” certificate includes a semplified declaration with no enclosures of documents related to the
materials used in the construction of the single sensor and guarantees the traceability of the materials through
the identification number of the thermometer. 
The data related to the origin of the materials can subsequently be requested by the client if necessary.

Further details

Maintenance 

The Omnigrad S TR62 thermometers do not require any specific maintenance.
In the case of ATEX certified components (transmitter, insert or thermowell) please refer to the corresponding
specific relevant documentation (at the end of the document).

Содержание Omnigrad S TR62 Series

Страница 1: ...nfigured with specific dimensions and characteristics depending on process requirements The installation on the plants require separately order of the thermowell form pipe or from bar stock Applicatio...

Страница 2: ...S TR62 temperature sensor is based on the following standards EN 50014 18 assembly Neck ASME style nipple and 3 elements coupling IEC 60751 insert The housing is in painted aluminium alloy it is suita...

Страница 3: ...he probe see fig 2A 2C Insulation of the outer part of the sensor reduces the effect produced by a low immersion Alternatively it is also possible to adopt a tilted installation see fig 2B 2D For a be...

Страница 4: ...term stability System components Housing The protection housing our TA21H commonly referred to the connection head is used to contain and protect the terminal block or the transmitter and to join the...

Страница 5: ...the transmitters can be easily programmed using a PC In the case of PROFIBUS PA transmitters E H recommends the use of PROFIBUS dedicated connectors The Weidm ller type is provided as a standard opti...

Страница 6: ...smitter can be executed with 3 wires as well by avoiding to connect whichever of the terminals fig 5 The configuration Pt100 double with 2 wires is only available for the ATEX intrinsically safe certi...

Страница 7: ...rective is not requested Material certification The material certificate EN 10204 3 1 can be directly selected from the sale structure of the product and refers to the parts of the sensor in contact w...

Страница 8: ...T M D 104 mm SS 316 NU 1 2 NPT F E 156 mm SS 316 NUN 1 2 NPT M F 77 mm A 105 N 1 2 NPT M G 117 mm A 105 N 1 2 NPT M H 104 mm A 105 NU 1 2 NPT F J 156 mm A 105 NUN 1 2 NPT M Y Special version to be spe...

Страница 9: ...pan 0 250 C A21 TMT180 A21 fixed range accuracy 0 2 K span limit 200 650 C from to C A22 TMT180 A22 fixed range accuracy 0 1 K span limit 50 250 C from to C F11 TMT181 A PCP 2 wire isolated programmab...

Страница 10: ...e head transmitter iTEMP PROFIBUS PA TMT184 TI079R 09 en RTD insert for temperature sensors Omniset TPR100 TI268T 02 en RTD insert for temperature sensors Omniset TPR300 TI290T 02 en Safety instructio...

Отзывы: