Tankvision
Connections to gauges and host systems
Hauser
19
Level Measurement - Continuous level measurement of powdery to granular bulk solids
e.g. plastic granulate and liquids.
– Measurement independent of density or bulk weight, conductivity, dielectric constant,
temperature and dust e.g. during pneumatic filling.
– Measurement is also possible in the event of foam or if the surface is very turbulent.
Interface measurement
Continuous measurement of interfaces between two liquids with very different dielectric
constants, such as in the case of oil and water for example.
The Levelflex M is communicating via the industry standard protocol HART and can be
connected to the Tankvision Tank Scanner via the Tank Side Monitor or an HART to
Modbus converter e.g. by Moore Industries. For more information see TI00358F/00/EN.
• Levelflex FMP5x
– FMP51
Premium device for level and interface measurement in liquids.
– FMP52
Premium device with coated probe for the use in aggressive liquids. Material of wetted
parts FDA listed and USP Class VI compliant.
– FMP54
Premium device for high-temperature and high-pressure applications, mainly in liquids.
Levelflex is communicating via the industry standard protocol HART and can be connected
to the Tankvision Tank Scanner via the Tank Side Monitor or an HART to Modbus
converter e.g. by Moore Industries. For more information see TI01001F/00/EN.
• Cerabar M
The Cerabar M pressure transmitter is used for the following measuring tasks:
– Absolute pressure and gauge pressure in gases, steams or liquids in all areas of process
engineering and process measurement technology.
– High reference accuracy: up to ±0.15%, as PLATINUM version: ±0.075%
Cerabar M is communicating via the industry standard protocol HART and can be
connected to the Tankvision Tank Scanner via the Tank Side Monitor or Proservo.
For more information see TI000436P/00/EN.
• Cerabar S
The Cerabar S pressure transmitter is used for the following measuring tasks:
– Absolute pressure and gauge pressure in gases, steams or liquids in all areas of process
engineering and process measurement technology.
– High reference accuracy: up to ±0.075%, as PLATINUM version: ±0.05%
Cerabar S is communicating via the industry standard protocol HART and can be connected
to the Tankvision Tank Scanner via the Tank Side Monitor or Proservo.
For more information see TI000383P/00/EN.
• Deltabar M
The Deltabar M differential pressure transmitter is used for the following measuring tasks:
– Flow measurement (volume or mass flow) in conjunction with primary elements in
gases, vaporss and liquids
– Level, volume or mass measurement in liquids
– Differential pressure monitoring, e.g. of filters and pumps
– High reference accuracy: up to ±0.1%, as PLATINUM version: ±0.075%
Deltabar M is communicating via the industry standard protocol HART and can be
connected to the Tankvision Tank Scanner via the Tank Side Monitor or Proservo.
For more information see TI000434P/00/EN.
• Deltabar S
The Deltabar S differential pressure transmitter is used for the following measuring tasks:
– Flow measurement (volume or mass flow) in conjunction with primary devices in gases,
vaporss and liquids
– Level, volume or mass measurement in liquids
– Differential pressure monitoring, e.g. of filters and pumps