Operating menu
Micropilot NMR84
136
Hauser
User entry
–213 to 927 °C
Factory setting
–100 °C
Additional information
Read access
Operator
Write access
Maintenance
Maximum probe temperature
Navigation
Setup → Advanced setup → Input/output → Analog IP → Max. probe temp
Prerequisite
Operating mode (→ 132)
RTD temperature input
Description
Maximum approved temperature of the connected probe.
If the temperature rises above this value, the W&M status will be 'invalid'.
User entry
–213 to 927 °C
Factory setting
250 °C
Additional information
Read access
Operator
Write access
Maintenance
Probe position
Navigation
Setup → Advanced setup → Input/output → Analog IP → Probe position
Prerequisite
Operating mode (→ 132)
RTD temperature input
Description
Position of the temperature probe, measured from zero position (tank bottom or datum
plate). This parameter, in conjunction with the measured level, determines whether the
temperature probe is still covered by the product. If this is no longer the case, the status of
the temperature value will be 'invalid'.
User entry
–5
000 to 30
000 mm
Factory setting
5
000 mm
Additional information
Read access
Operator
Write access
Maintenance
Содержание Micropilot NMR84
Страница 177: ...Micropilot NMR84 Operating menu Endress Hauser 177 Additional information Read access Operator Write access Maintenance ...
Страница 204: ...Operating menu Micropilot NMR84 204 Endress Hauser Additional information Read access Operator Write access Maintenance ...
Страница 219: ...Micropilot NMR84 Operating menu Endress Hauser 219 Additional information Read access Operator Write access Maintenance ...
Страница 238: ...Operating menu Micropilot NMR84 238 Endress Hauser Read access Operator Write access Maintenance ...
Страница 255: ......
Страница 256: ...www addresses endress com 71545626 71545626 ...