Micropilot FMR67
30
V. 1, Rev. 3, 11-04-2017
Hauser
H
max
øD
A0032209
Inner nozzle diameter
D
Maximum nozzle height
H
max
min. 50 mm (2 in)
≤150 mm (6 in)
80 mm (3 in)
≤200 mm (8 in)
100 mm (4 in)
≤300 mm (12 in)
150 mm (6 in)
≤500 mm (20 in)
Note the following if the antenna does not project out of the nozzle:
• The end of the nozzle must be smooth and free from burrs. The edge of the nozzle should be
rounded if possible.
• Mapping must be performed.
• Please contact Hauser for applications with nozzles that are higher than indicated in
the table.
Information concerning threaded connections
• When screwing in, turn by the hex bolt only.
• Tool: open-ended wrench 55 mm
• Maximum permissible torque: 50 Nm (36 lbf ft)
Installation: flush mount
antenna
Aligning the antenna axis
UNI flanges with an integrated alignment unit are available for FMR67 devices with a flush mount
antenna. An angle of inclination of up to 15° in all directions can be set for the antenna axis using
the alignment unit. The alignment unit is used to optimally align the radar beam to the bulk solid.
Process connection with
alignment unit
UNI flange
Material
Pressure rating
Suitable for
XCA
UNI 4" / DN100 / 100A
Aluminum max. 14.5lbs / PN1 / 1K • 4" 150lbs
• DN100 PN16
• 10K 100A
XDA
UNI 6" / DN150 / 150A
Aluminum max. 14.5lbs / PN1 / 1K • 6" 150lbs
• DN150 PN16
• 10K 150A
XEA
UNI 8" / DN200 / 200A
Aluminum max. 14.5lbs / PN1 / 1K • 8" 150lbs
• DN200 PN16
• 10K 200A
XFA
UNI 10" / DN250 / 250A Aluminum max. 14.5lbs / PN1 / 1K • 10" 150lbs
• DN250 PN16
• 10K 250A
1)
Feature 100 in the product structure