Micropilot FMR66B HART
50
V. 1, Rev. 2, 26-07-2022
Hauser
A
B
C
D
E
A0046692
A
Plastic single compartment housing, remote display
B
Aluminum single compartment housing, remote display
C
Device side, plastic single compartment housing prepared for remote display
D
Device side, aluminum single compartment housing prepared for remote display
E
Device side, dual compartment housing, L-form, prepared for remote display
Material of single compartment housing, remote display
• Aluminum
• Plastic
Degree of protection:
• IP68 / NEMA 6P
• IP66 / NEMA 4x
Connecting cable:
• Connecting cable (option) up to 30 m (98 ft)
• Standard cable provided by customer onsite up to 60 m (196 ft)
Ambient temperature:
• –40 to +80 °C (–40 to +176 °F)
• Option: –50 to +80 °C (–58 to +176 °F)
Commubox FXA195 HART
For intrinsically safe HART communication with FieldCare via the USB interface
For details, see "Technical Information" TI00404F
HART Loop Converter
HMX50
Is used to evaluate and convert dynamic HART process variables to analog current signals or limit
values.
Order number:
71063562
For details, see "Technical Information" TI00429F and Operating Instructions BA00371F
FieldPort SWA50
Intelligent Bluetooth® and/or WirelessHART adapter for all HART field devices
For details, see "Technical Information" TI01468S
Wireless HART adapter
SWA70
The WirelessHART adapter is used for the wireless connection of field devices. It can be easily
integrated into field devices and existing infrastructures, offers data protection and transmission
safety and can be operated in parallel with other wireless networks.
For details, see Operating Instructions BA00061S