Micropilot FMR66B HART
Hauser
V. 1, Rev. 2, 26-07-2022
41
• NAMUR NE 107
Status categorization in accordance with NE 107
• NAMUR NE 131
Requirements for field devices for standard applications
• IEC 61508
Functional safety of safety-related electric/electronic/programmable electronic systems
Ordering information
Detailed ordering information is available from your nearest sales organization
www.addresses.endress.com
or in the Product Configurator at
www.endress.com
:
1. Select the product using the filters and search field.
2. Open the product page.
3. Select
Configuration
.
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Hauser Online Shop
Calibration
Factory calibration certificate
The points of the linearity protocol are spread evenly over the measuring range (0 to 100 %). The
Empty calibration
E
and Full calibration
F
must be specified to define the measuring range. If this
information is missing, antenna-dependent default values are used instead.
R
A
F
E
100%
0%
A0032643
R
Reference point of measurement
A
Minimum distance between reference point R and 100% mark
E
Empty calibration
F
Full calibration