Storage and transport
Micropilot FMR63B HART
8
Hauser
9
Storage and transport
9.1
Storage conditions
• Use the original packaging
• Store the device in clean and dry conditions and protect from damage caused by shocks
9.1.1
Storage temperature range
See Technical Information.
9.2
Transporting the product to the measuring point
L
WARNING
Incorrect transport!
The housing or sensor can be damaged or pull off. Risk of injury!
‣
Transport the device to the measuring point in its original packaging or by the process
connection.
‣
Always secure lifting equipment (slings, eyes, etc.) at the process connection and never lift
the device by the electronic housing or sensor. Pay attention to the center of gravity of the
device so that it does not tilt or slip unintentionally.
10
Installation
10.1 General instructions
L
WARNING
Loss of protection rating if the device is opened in a wet environment.
‣
Only open the device in a dry environment!
1. Install the device or turn the housing so that the cable entries do not point upwards.
A0029263
2. Always firmly tighten the housing cover and the cable entries.
3. Counter-tighten the cable entries.
4. A drip loop must be provided when laying the cables.
Содержание Micropilot FMR63B