Functional Safety Manual
for the Memosens transmitter Liquiline M CM42 SIL
Version:
Page:
2.0
22
of
72
A
ll
e
R
ec
h
te
v
o
rb
eh
al
te
n
.
D
as
K
o
p
ie
re
n
d
ie
se
s
D
o
k
u
m
en
ts
u
n
d
d
ie
V
er
w
en
d
u
n
g
v
o
n
T
ei
le
n
au
s
d
ie
se
m
D
o
k
u
m
en
t
is
t
o
h
n
e
sc
h
ri
ft
li
ch
e
G
en
eh
m
ig
u
n
g
d
er
E
n
d
re
ss
+
H
au
se
r
C
o
n
d
u
ct
a
G
m
b
H
+
C
o
.
K
G
n
ic
h
t
er
la
u
b
t.
A
ll
ri
gh
ts
re
se
rv
ed
.
P
as
si
n
g
o
n
an
d
co
p
yi
n
g
o
f
th
is
d
o
cu
m
en
t,
u
se
an
d
co
m
m
u
n
ic
at
io
n
o
f
it
s
co
n
te
n
ts
n
o
t
p
er
m
it
te
d
w
it
h
o
u
t
w
ri
tt
en
au
th
o
ri
za
ti
o
n
fr
o
m
E
n
d
re
ss
+
H
au
se
r
C
o
n
d
u
ct
a
G
m
b
H
+
C
o
.
K
G
.
Functional safety parameters
Specific functional safety parameters for single-channel device operation:
Parameters according to
IEC 61508
Liquiline M CM42, Memosens
Safety function
1: pH limit monitoring
2: pH value measurement
3 and 4: safe calibration / adjustment
See also chapter
Fehler! Verweisquel-
le konnte nicht gefunden werden.
for details.
SIL
Hardware: 2, Software: 2
in homogenous redundancy: 2
HFT
0
Device type
B
Mode of operation
Low demand mode
SFF
94.8 %
MTTR (used for PFD calculation)
8 h
T
1
(Proof test interval)
Recommended 1 year (see chart below)
SD
688 FIT
SU
947 FIT
DD
2667 FIT
DU
236 FIT
Total
*1
4549 FIT
PFD
avg
(for T
1
= 1 year)
*4
1.03
×
10
-3
PFH
2.36
×
10
-7
MTBF / MTBF
DU
*1
25 years / 483 years
Diagnostic test interval
*2
< 60 min (without RAM-test: <10 min)
Error reaction time
*3
< 1 second