Temperature head transmitter
4 Installation
25
4.2
Installation
Installation
For installation proceed as follows:
Installing in a sensor connection head to DIN 43 729 Form B (s. fig. 4, left side)
•
Feed the sensor inset cables (Pos. 5) through the central hole in the head transmitter
(Pos. 4).
•
Place the installation springs (Pos. 3) onto the screws (Pos. 2).
•
Feed the installation screws (Pos. 2) through the holes in the head transmitter and the
holes in the sensor inset (Pos. 5). Fix both screws using the circlips (Pos. 6).
•
Position the head transmitter in the connection head in such a way so that the current
output terminals (terminal 1 and 2) are towards the cable entry gland (Pos. 7).
•
Fix the head transmitter (Pos. 4) and sensor inset (Pos. 5) into the connection head.
Installation in a field housing (s. fig. 4 , right side)
•
Feed the installation screws (Pos. 2) with installation springs (Pos. 3) through the holes
in the head transmitter (Pos. 4). Fix these using the circlips (Pos. 5).
•
Screw the head transmitter into the field housing using a screw driver.
A
Attention!
In order to avoid damaging the head transmitter do not over tighten the installation
screws.
Fig. 4:
Installation of head transmitter into a Form B sensor connection head (left side) and a field housing
(right side).
R-T
M
T
187Z
X
-17
-0
6-06-en-001.
eps
R-T
M
T
1
8
7
Z
X
-17-06-06-en-002.
eps