Installation instructions
TMT162 HART
22
Hauser
2.3.2
Remote mounting
A0003586-DE
Fig. 3: Installation of the field transmitter using the mounting kit. Dimensions in mm (inch)
Pos. A, B Mounting with combined wall/pipe mounting kit
Pos. C Mounting with pipe mounting kit 2"/V4A
2.4
Post-installation check
After installing the device, always run the following final checks:
Device condition and specifications
Notes
Is the device visibly free of damage (visual check)?
-
Does the device comply to the measurement point
specifications, such as ambient temperature, etc.?