Mounting
Micropilot FMR56, FMR57 FOUNDATION Fieldbus
8
Hauser
5
Mounting
5.1
Mounting location
A
1
2
3
A0016883
A
Recommended distance from wall to nozzle outer edge ~ 1/6 of the vessel diameter. However, the
device must not under any circumstances be mounted closer than 20 cm (7.87 in) to the vessel wall. If
the vessel wall is not smooth (corrugated iron, welding seams, joints, etc.), it is advisable to maintain
the greatest possible distance from the wall. Where necessary, use an alignment unit to avoid
interference reflections from the vessel wall .
1
Use of a weather protection cover; protection from direct sunlight or rain
2
Installation in the center, interference can cause signal loss
3
Do not install above the filling curtain
In applications with strong dust emissions, the integrated purge air connection can
prevent the antenna from becoming clogged.