Mounting
Micropilot FMR51, FMR52 FOUNDATION Fieldbus
16
Hauser
Information concerning nozzles
H
ma
x
A0016819
3
Nozzle height for horn antenna, flush mount (FMR52)
Antenna
Maximum nozzle height
H
max
Horn 50mm/2"
500 mm (19.7 in)
Horn 80mm/3"
500 mm (19.7 in)
• For flanges with PTFE cladding: Observe the instructions for mounting cladded flanges
• The PTFE flange cladding normally acts simultaneously as a seal between the nozzle
and the device flange
• Please contact the manufacturer's support service for applications with nozzles that are
higher than indicated in the table.
Mounting cladded flanges
Note the following for cladded flanges:
• Use the same number of flange screws as the number of flange bores provided.
• Tighten the screws with the necessary torque (see Table).
• Retighten after 24 hours or after the first temperature cycle.
• Depending on the process pressure and temperature, check and retighten the screws,
where necessary, at regular intervals.
The PTFE flange cladding normally acts simultaneously as a seal between the nozzle and
the device flange.
Flange size
Number of screws
Tightening torque
EN
DN50 PN10/16
4
45 to 65 Nm
DN50 PN25/40
4
45 to 65 Nm
DN80 PN10/16
8
40 to 55 Nm
DN80 PN25/40
8
40 to 55 Nm
DN100 PN10/16
8
40 to 60 Nm
DN100 PN25/40
8
55 to 80 Nm