Flowmeter Proline 500
Electrical connection
Hauser
21
2. In the case of the coil current cable:
Insulate one core of the three-core cable at the level of the core reinforcement. You only
require two cores for the connection.
3. For cables with fine-wire cores (stranded cables):
Fit the cores with ferrules.
Preparing the connecting cable: Promag H
Transmitter
Electrode cable
Coil current cable
A
80 (3.15)
50 (1.97)
17 (0.67)
8 (0.3)
B
GND
1
2
1
2
1
2
2
A0029543
A
70 (2.76)
50 (1.97)
10 (0.4)
8 (0.3)
B
1
A0029544
Engineering unit mm (in)
A = Terminate the cable
B = Fit ferrules on cables with fine-wire cores (stranded cables)
1 = Red ferrules, 1.0 mm (0.04 in)
2 = White ferrules, 0.5 mm (0.02 in)