background image

Products

Solutions

Services

Brief Operating Instructions

CNGmass

Coriolis flowmeter

These Instructions are Brief Operating Instructions; they are

not a substitute for the Operating Instructions pertaining to

the device.
Detailed information about the device can be found in the

Operating Instructions and the other documentation:

• On the CD-ROM supplied (not included in the delivery for all

device versions).

• Available for all device versions via:

– Internet: 

www.endress.com/deviceviewer

– Smart phone/tablet: 

Hauser Operations App

KA01170D/06/EN/03.15

71301661

Содержание CNGmass

Страница 1: ...Instructions pertaining to the device Detailed information about the device can be found in the Operating Instructions and the other documentation On the CD ROM supplied not included in the delivery...

Страница 2: ...CNGmass 2 Endress Hauser TAG No XXX000 Ser No X000X000000 Order code 00X00 XXXX0XX0XXX www endress com deviceviewer Endress Hauser Operations App Serial number A0023555...

Страница 3: ...t 13 6 Installation 14 6 1 Installation conditions 14 6 2 Mounting the measuring device 15 6 3 Post installation check 16 7 Electrical connection 17 7 1 Connection conditions 17 7 2 Connecting the mea...

Страница 4: ...ymbols Symbol Meaning A0011197 Direct current A terminal to which DC voltage is applied or through which direct current flows A0011198 Alternating current A terminal to which alternating voltage is ap...

Страница 5: ...re preferred A0011184 Forbidden Indicates procedures processes or actions that are forbidden A0011193 Tip Indicates additional information A0011194 Reference to documentation Refers to the correspondi...

Страница 6: ...nditions 2 2 Designated use Application and media The measuring device described in these Instructions is intended only for flow measurement of liquids and gases Depending on the version ordered the m...

Страница 7: ...minute changes in the temperature concentration or level of contamination in the process can alter the corrosion resistance properties Residual risks The external surface temperature of the housing ca...

Страница 8: ...C Declaration of Conformity Endress Hauser confirms this by affixing the CE mark to the device 2 6 IT security We only provide a warranty if the device is installed and used as described in the Operat...

Страница 9: ...dbus RS485 communication types 2 3 4 1 A0017609 1 Important components of a measuring device 1 Transmitter housing cover 2 Main electronics module 3 Transmitter housing 4 Sensor In the case of the dev...

Страница 10: ...A0013699 Do the nameplate data match the ordering information on the delivery note A0015502 A0013697 Is the CD ROM with the Technical Documentation depends on device version and documents present If...

Страница 11: ...g device is displayed Order code Ext ord cd Ser no 1 2 3 4 A0021952 2 Example of a nameplate 1 Order code 2 Serial number Ser no 3 Extended order code Ext ord cd 4 2 D matrix code QR code For detailed...

Страница 12: ...p The Endress Hauser Operations App is available both for android smart phones Google Play store and for iPhones and iPads App Store Via the serial number 1 Launch the Endress Hauser Operations App 2...

Страница 13: ...ng Observe the weight specified on the packaging stick on label Observe the transport instructions on the stick on label on the electronics compartment cover A0015606 Observe the following notes durin...

Страница 14: ...process Ambient temperature range Measuring device 40 to 60 C 40 to 140 F Safety Barrier Promass 100 40 to 60 C 40 to 140 F If operating outdoors Avoid direct sunlight particularly in warm climatic r...

Страница 15: ...required Experience shows that zero point adjustment is advisable only in special cases To achieve maximum measuring accuracy even with low flow rates Under extreme process or operating conditions e...

Страница 16: ...vice undamaged visual inspection Does the measuring device conform to the measuring point specifications For example Process temperature Process pressure refer to the chapter on Material load curves o...

Страница 17: ...wing requirements Electrical safety In accordance with applicable federal national regulations Permitted temperature range 40 C 40 F to 80 C 176 F Minimum requirement cable temperature range ambient t...

Страница 18: ...with the maximum cable resistance specifications to ensure the operational reliability of the measuring device Wire cross section Maximum cable length mm2 AWG m ft 0 5 20 70 230 0 75 18 100 328 1 0 17...

Страница 19: ...inals Option B thread M20x1 Option C thread G Option D thread NPT Order code for Housing Option A compact coated aluminum L L 62 72 A B 10 20 _ 1 2 A0017053 4 Modbus RS485 terminal assignment connecti...

Страница 20: ...y EMC Explosion protection Personal protection equipment National installation regulations and guidelines Observe cable specification 17 Keep the stripped and twisted lengths of cable shield to the gr...

Страница 21: ...suitable cable gland for corresponding connecting cable 17 3 If measuring device is delivered with cable glands Observe cable specification 17 7 2 Connecting the measuring device NOTICE Limitation of...

Страница 22: ...ersions with connection example 1 Cable Connect the cable in accordance with the terminal assignment 7 2 2 Connecting the Safety Barrier Promass 100 In the case of the device version with Modbus RS485...

Страница 23: ...Safety Barrier Promass 100 terminal assignment 20 4 Observe cable specification 17 5 Non hazardous area 6 Non hazardous area and Zone 2 Div 2 7 Intrinsically safe area 8 Transmitter terminal assignme...

Страница 24: ...g the degree of protection The measuring device fulfills all the requirements for the IP66 67 degree of protection Type 4X enclosure To guarantee IP66 67 degree of protection Type 4X enclosure carry o...

Страница 25: ...ned and leak tight Cable run with water trap 24 Does the supply voltage match the specifications on the transmitter nameplate For device version with Modbus RS485 intrinsically safe does the supply vo...

Страница 26: ...58 EN 10 Schematic structure of the operating menu 8 1 2 Operating philosophy The individual parts of the operating menu are assigned to certain user roles Each user role corresponds to typical tasks...

Страница 27: ...ection For device version with Modbus RS485 communication type Via service interface CDI and FieldCare operating tool 1 Start FieldCare and launch the project 2 In the network Add a device The Add dev...

Страница 28: ...ain all the parameters required for configuration such as parameters for measurement or communication Submenu Meaning System units Configuring the units for all measured values Medium selection Defini...

Страница 29: ...ation types OFF ON 1 Write protection 2 Not used 3 Not used 4 Not used A0022571 Setting the write protection switch on the electronics module to the ON position enables the hardware write protection I...

Страница 30: ......

Страница 31: ......

Страница 32: ...www addresses endress com...

Отзывы: