Ceraphant PTC31B, PTP31B, PTP33B IO-Link
Technical data
Hauser
77
17
Technical data
17.1 Input
17.1.1 Measured variable
Measured process variable
Gauge pressure or absolute pressure
Calculated process variable
Pressure
17.1.2 Measuring range
Ceramic process isolating diaphragm
Sensor
Device
Maximum
Sensor measuring range
Lowest
calibratable
span
MWP
OPL
Factory settings
Option
lower (LRL) upper (URL)
[bar (psi)]
[bar (psi)]
[bar (psi)]
[bar (psi)]
[bar (psi)]
Devices for gauge pressure measurement
100 mbar (1.5 psi)
PTC31B –0.1 (–1.5)
+0.1 (+1.5)
0.02 (0.3)
2.7 (40.5)
4 (60)
0 to 100 mbar (0 to 1.5 psi)
1C
250 mbar (4 psi)
PTC31B –0.25 (–4)
+0.25 (+4)
0.05 (1)
3.3 (49.5)
5 (75)
0 to 250 mbar (0 to 4 psi)
1E
400 mbar (6 psi)
PTC31B –0.4 (–6)
+0.4 (+6)
0.08 (1.2)
5.3 (79.5)
8 (120)
0 to 400 mbar (0 to 6 psi)
1F
1 bar (15 psi)
PTC31B –1 (–15)
+1 (+15)
0.2 (3)
6.7 (100.5)
10 (150)
0 to 1 bar (0 to 15 psi)
1H
2 bar (30 psi)
PTC31B –1 (–15)
+2 (+30)
0.4 (6)
12 (180)
18 (270)
0 to 2 bar (0 to 30 psi)
1K
4 bar (60 psi)
PTC31B –1 (–15)
+4 (+60)
0.8 (12)
16.7 (250.5) 25 (375)
0 to 4 bar (0 to 60 psi)
1M
10 bar (150 psi)
PTC31B –1 (–15)
+10 (+150)
2 (30)
26.7 (400.5) 40 (600)
0 to 10 bar (0 to 150 psi)
1P
40 bar (600 psi)
PTC31B –1 (–15)
+40 (+600)
8 (120)
40 (600)
60 (900)
0 to 40 bar (0 to 600 psi)
1S
Devices for absolute pressure measurement
100 mbar (1.5 psi)
PTC31B 0
+0.1 (+1.5)
0.1 (1.5)
2.7 (40.5)
4 (60)
0 to 100 mbar (0 to 1.5 psi)
2C
250 mbar (4 psi)
PTC31B 0
+0.25 (+4)
0.25 (4)
3.3 (49.5)
5 (75)
0 to 250 mbar (0 to 4 psi)
2E
400 mbar (6 psi)
PTC31B 0
+0.4 (+6)
0.4 (6)
5.3 (79.5)
8 (120)
0 to 400 mbar (0 to 6 psi)
2F
1 bar (15 psi)
PTC31B 0
+1 (+15)
0.4 (6)
6.7 (100.5)
10 (150)
0 to 1 bar (0 to 15 psi)
2H
2 bar (30 psi)
PTC31B 0
+2 (+30)
0.4 (6)
12 (180)
18 (270)
0 to 2 bar (0 to 30 psi)
2K
4 bar (60 psi)
PTC31B 0
+4 (+60)
0.8 (12)
16.7 (250.5) 25 (375)
0 to 4 bar (0 to 60 psi)
2M
10 bar (150 psi)
PTC31B 0
+10 (+150)
2 (30)
26.7 (400.5) 40 (600)
0 to 10 bar (0 to 150 psi)
2P
40 bar (600 psi)
PTC31B 0
+40 (+600)
8 (120)
40 (600)
60 (900)
0 to 40 bar (0 to 600 psi)
2S
1)
Highest turn down that can be set at the factory: 5:1. The turn down is preset and cannot be changed.
2)
Other measuring ranges (e.g. –1 to +5 bar (–15 to 75 psi)) can be ordered with customer-specific settings (see the Product Configurator, order
code for "Calibration; Unit" option "U"). It is possible to invert the output signal (LRV = 20 mA; URV = 4 mA). Prerequisite: URV < LRV
3)
Product Configurator, order code for "Sensor range"
4)
Vacuum resistance: 0.7 bar (10.5 psi) abs
5)
Vacuum resistance: 0.5 bar (7.5 psi) abs
6)
Vacuum resistance: 0 bar (0 psi) abs
Содержание Ceraphant PTP31B