Programming
In the »programming« mode, you can set the
parameters for the automatic mode:
• Type of cleaning
−
Off
−
Interval cleaning with fixed intervals
(10 min 99 h)
−
Weekly program with 12 starting times
per day, individually adjustable for
each day of the week
• Cleaning cycle
−
Pre-rinse time t
1
(1…. 60 s)
−
Cleaning time t
2
(1.… 60 s)
−
Post-rinse time t
3
(1…. 60 s)
−
Economy function, i.e. every x
th
cleaning
cycle (x = 1 ... 9) is performed with
cleaner; water rinse is used for remaining
cycles
• Time of day (24-hour representation)
6.1.2
External control
The program sequencer is equipped with
contact inputs and outputs for communication
with other devices.
The inputs can be used to start a cleaning
cycle externally or to inhibit the start of a clea-
ning cycle to prevent the cleaner from
influencing important control processes.
Note:
•
An ongoing cleaning cycle cannot
be interrupted.
•
An external start in the »service«
mode is not possible.
•
When an external stop has been
issued, the unit cannot be opera-
ted via the keypad.
Time [s]
3
3
t1
t2
t3
3
10
Start
Hold 1
Hold 2
Drive water
Cleaning
agent
Probfit
Stop
Enable
Enable
ZY
K
L
US
1
.CDR
Fig. 6.2
Cleaning cycle
sequence
06PC20.CHP
autoclean CPC 20 / CPC 20-Z